English
Language : 

M3727GM6 Datasheet, PDF (73/129 Pages) Renesas Technology Corp – SINGLE-CHIP 8-BIT CMOS MICROCOMPUTER with CLOSED CAPTION DECODER and ON-SCREEN DISPLAY CONTROLLER
M3727GM6/M8–XXXSP/FP M37272E8SP/FP
Notes 1 : The 80-byte addresses corresponding to the character code “7F16”
and “8016” in OSD ROM are the test data storing area. Set data to
the area as follows.
<Test data storing area>
■ M37272M6/M8-XXXSP/FP, M37272E8SP/FP
addresses 100016 + (4 + 2n) ✕ 10016 + FE16 to
100016 + (5 + 2n) ✕ 10016 + 0116
(n = 0 to 19)
(1)Mask version (M3727GM6/M8-XXXSP/FP)
Set “FF16” to the area (We stores the test data to this area and the different
data from “FF16” is stored for the actual products.) When using our font
editor, the test data is written automatically.
(2)EPROM version (M37272E8SP/FP)
Set the test data to the area. When using our font editor, the test data
is written automatically.
■M37272E8SP/FP
<“FF16”> address (test data)
14FE16 (0916), 14FF16 (5116)
16FE16 (0016), 16FF16 (5216)
18FE16 (1216), 18FF16 (5316)
1AFE16 (0016), 1AFF16 (5416)
1CFE16 (2416), 1CFF16 (5516)
1EFE16 (0016), 1EFF16 (5616)
20FE16 (8816), 20FF16 (5716)
22FE16 (0016), 22FF16 (5816)
24FE16 (9016), 24FF16 (5916)
26FE16 (4816), 26FF16 (5A16)
28FE16 (2416), 28FF16 (5B16)
2AFE16 (0016), 2AFF16 (5C16)
2CFE16 (2416), 2CFF16 (5D16)
2EFE16 (4816), 2EFF16 (5E16)
30FE16 (0016), 30FF16 (5F16)
32FE16 (4816), 32FF16 (5016)
34FE16 (9016), 34FF16 (5116)
36FE16 (0016), 36FF16 (5216)
38FE16 (0116), 38FF16 (5316)
3AFE16 (8016), 3AFF16 (5416)
<“8016”> address (test data)
150016 (9016), 150116 (A116)
170016 (0016), 170116 (A216)
190016 (4816), 190116 (A316)
1B0016 (0016), 1B0116 (A416)
1D0016 (2416), 1D0116 (A516)
1F0016 (0016), 1F0116 (A616)
210016 (1216), 210116 (A716)
230016 (0016), 230116 (A816)
250016 (0916), 250116 (A916)
270016 (0016), 270116 (AA16)
290016 (8116), 290116 (AB16)
2B0016 (1816), 2B0116 (AC16)
2D0016 (0016), 2D0116 (AD16)
2F0016 (4216), 2F0116 (AE16)
310016 (2416), 310116 (AF16)
330016 (0016), 330116 (B016)
350016 (8116), 350116 (B116)
370016 (0C16), 370116 (B216)
390016 (0616), 390116 (B316)
3B0016 (0016), 3B0116 (B416)
2 : The character code “0916” is used for “transparent space” when
displaying Closed Caption.
Therefore, set “0016” to the 40-byte addresses corresponding to the
character code “0916.”
<Transparent space font data storing area>
■ M3727GM6/M8-XXXSP/FP, M37272E8SP/FP
addresses 100016 + (4 + 2n) ✕ 10016 + 1216 to
100016 + (4 + 2n) ✕ 10016 + 1316
(n = 0 to 19)








addresses
addresses
addresses
addresses
141216
161216
381216
3A1216
and
and
and
and
141316


161316 


381316 
3A1316
Rev.1.00 Apr 01, 2001 page 73 of 127
REJ03B0132-0100Z