Table 2.10 Addressing Modes
No.
Addressing Mode
1
Register direct
2
Register indirect
3
Register indirect with displacement
4
Register indirect with post-increment
Register indirect with pre-decrement
5
Absolute address
6
Immediate
7
Program-counter relative
8
Memory indirect
Section 2 CPU
Symbol
Rn
@ERn
@(d:16,ERn)/@(d:24,ERn)
@ERn+
@–ERn
@aa:8/@aa:16/@aa:24
#xx:8/#xx:16/#xx:32
@(d:8,PC)/@(d:16,PC)
@@aa:8
Register Direct—Rn
The register field of the instruction specifies an 8-, 16-, or 32-bit general register containing the
operand. R0H to R7H and R0L to R7L can be specified as 8-bit registers. R0 to R7 and E0 to E7
can be specified as 16-bit registers. ER0 to ER7 can be specified as 32-bit registers.
Register Indirect—@ERn
The register field of the instruction code specifies an address register (ERn), the lower 24 bits of
which contain the address of the operand on memory.
Register Indirect with Displacement—@(d:16, ERn) or @(d:24, ERn)
A 16-bit or 24-bit displacement contained in the instruction is added to an address register (ERn)
specified by the register field of the instruction, and the lower 24 bits of the sum the address of a
memory operand. A 16-bit displacement is sign-extended when added.
Register Indirect with Post-Increment or Pre-Decrement—@ERn+ or @-ERn
• Register indirect with post-increment—@ERn+
The register field of the instruction code specifies an address register (ERn) the lower 24 bits
of which contains the address of a memory operand. After the operand is accessed, 1, 2, or 4 is
added to the address register contents (32 bits) and the sum is stored in the address register.
The value added is 1 for byte access, 2 for word access, or 4 for longword access. For the word
or longword access, the register value should be even.
Rev.5.00 Nov. 02, 2005 Page 35 of 418
REJ09B0028-0500