English
Language : 

R01DS0190EJ0100 Datasheet, PDF (49/110 Pages) Renesas Technology Corp – 32 MHz 32-bit RX MCUs, 50 DMIPS, up to 128 Kbytes of flash memory
RX111 Group
5. Electrical Characteristics
5. Electrical Characteristics
5.1 Absolute Maximum Ratings
Table 5.1 Absolute Maximum Ratings
Conditions: VSS = AVSS0 = VREFL0 = VSS_USB = 0 V
Item
Symbol
Value
Unit
Power supply voltage
VCC, VCC_USB
–0.3 to +4.6
V
Input voltage (except for ports for 5 V tolerant*1)
Vin
Input voltage (ports for 5 V tolerant*1)
Vin
–0.3 to VCC +0.3
V
–0.3 to +6.5
V
Reference power supply voltage
VREFH0
–0.3 to AVCC +0.3
V
Analog power supply voltage
Analog input voltage
Operating temperature*2
AVCC0
VAN
Topr
–0.3 to +4.6
V
–0.3 to +4.6
V
–0.3 to AVCC + 0.3
°C
(when AN000 to AN004 and AN006 used)
–0.3 to VCC + 0.3
(when AN008 to AN015 used)
Storage temperature
Tstg
–55 to +125
°C
Caution: Permanent damage to the MCU may result if absolute maximum ratings are exceeded.
To preclude any malfunctions due to noise interference, insert capacitors of high frequency characteristics between the VCC and
VSS pins, between the AVCC0 and AVSS0 pins, between the VCC_USB and VSS_USB pins, and between the VREFH0 and
VREFL0 pins. Place capacitors of about 0.1 μF as close as possible to every power supply pin and use the shortest and heaviest
possible traces. Also, connect capacitors as stabilization capacitance.
Connect the VCL pin to a VSS pin via a 4.7 µF capacitor. The capacitor must be placed close to the pin.
Note 1. Ports 16, 17, A6, and B0 are 5 V tolerant.
Do not input signals or an I/O pull-up power supply while the device is not powered. The current injection that results from input
of such a signal or I/O pull-up may cause malfunction and the abnormal current that passes in the device at this time may cause
degradation of internal elements.
Note 2. The upper limit of operating temperature is 85°C or 105°C, depending on the product. For details, refer to 1.2 List of Products.
Table 5.2 Recommended Operating Voltage Conditions
Item
Recommended operating voltage conditions
Symbol
Value
Unit
VCC, VCC_USB*1
1.8 to 3.6 (during no USB communication)
V
3.0 to 3.6 (during USB communication)
AVCC0*2
1.8 to 3.6
V
Note 1. Set VCC and VCC_USB to the same potential. Also, set VSS, AVSS0, and VSS_USB to the same potential.
Note 2. AVCC0 and VCC can be set individually within the operating range. For details, 30.7.10 Voltage Range of Analog Power Supply
Pins.
R01DS0190EJ0100 Rev.1.00
Jun 19, 2013
Page 49 of 107