English
Language : 

32192 Datasheet, PDF (378/1044 Pages) Renesas Technology Corp – MCU
10
MULTIJUNCTION TIMERS
10.3 TOP (Output-Related 16-Bit Timer)
10.3.8 TOP Enable Control Registers
TOP0–10 External Enable Permit Register (TOPEEN)
<Address: H’0080 02FA>
b0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 b15
TOP10 TOP9 TOP8 TOP7 TOP6 TOP5 TOP4 TOP3 TOP2 TOP1 TOP0
EEN EEN EEN EEN EEN EEN EEN EEN EEN EEN EEN
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
b
Bit Name
0–4
No function assigned. Fix to "0."
5
TOP10EEN (TOP10 external enable permit bit)
6
TOP9EEN (TOP9 external enable permit bit)
7
TOP8EEN (TOP8 external enable permit bit)
8
TOP7EEN (TOP7 external enable permit bit)
9
TOP6EEN (TOP6 external enable permit bit)
10
TOP5EEN (TOP5 external enable permit bit)
11
TOP4EEN (TOP4 external enable permit bit)
12
TOP3EEN (TOP3 external enable permit bit)
13
TOP2EEN (TOP2 external enable permit bit)
14
TOP1EEN (TOP1 external enable permit bit)
15
TOP0EEN (TOP0 external enable permit bit)
Note: • This register must always be accessed in halfwords.
Function
0: Disable external enable
1: Enable external enable
<Upon exiting reset: H’0000>
RW
00
RW
The TOP0–10 External Enable Permit Register controls enable operation on TOP counters from external de-
vices by enabling or disabling it.
TOP0–10 Enable Protect Register (TOPPRO)
<Address: H’0080 02FC>
b0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 b15
TOP10 TOP9 TOP8 TOP7 TOP6 TOP5 TOP4 TOP3 TOP2 TOP1 TOP0
PRO PRO PRO PRO PRO PRO PRO PRO PRO PRO PRO
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
b
Bit Name
0–4
No function assigned. Fix to "0."
5
TOP10PRO (TOP10 enable protect bit)
6
TOP9PRO (TOP9 enable protect bit)
7
TOP8PRO (TOP8 enable protect bit)
8
TOP7PRO (TOP7 enable protect bit)
9
TOP6PRO (TOP6 enable protect bit)
10
TOP5PRO (TOP5 enable protect bit)
11
TOP4PRO (TOP4 enable protect bit)
12
TOP3PRO (TOP3 enable protect bit)
13
TOP2PRO (TOP2 enable protect bit)
14
TOP1PRO (TOP1 enable protect bit)
15
TOP0PRO (TOP0 enable protect bit)
Note: • This register must always be accessed in halfwords.
Function
0: Enable for rewriting
1: Protect against rewriting
<Upon exiting reset: H’0000>
RW
00
RW
The TOP0–10 Enable Protect Register controls rewriting of the TOP count enable bit by enabling for or protect-
ing it against rewriting.
32192/32195/32196 Group Hardware Manual
Rev.1.10 REJ09B0123-0110 Apr.06.07
10-74