English
Language : 

HD404629R Datasheet, PDF (34/157 Pages) Renesas Technology Corp – AS Microcomputer Incorporating a DTMF Generator Circuit
HD404629R Series
Table 20 Operations in Low-Power Dissipation Modes
Function
Stop Mode
Watch Mode
Standby Mode
Subactive Mode*2
CPU
Reset
Retained
Retained
OP
RAM
Retained
Retained
Retained
OP
Timer A
Reset
OP
OP
OP
Timer B
Reset
Stopped
OP
OP
Timer C
Reset
Stopped
OP
OP
Timer D
Reset
Stopped
OP
OP
Serial interface Reset
Stopped*3
OP
OP
A/D
Reset
Stopped
OP
Stopped
LCD
Reset
OP *4
OP
OP
DTMF
Reset
Reset
Stopped
Reset
I/O
Reset*1
Retained
Retained
OP
Notes: OP implies in operation.
1. Output pins are at high impedance.
2. Subactive mode is an optional function specified on the function option list.
3. Transmission/Reception is activated if a clock is input in external clock mode. However,
interrupts stop.
4. When a 32-kHz clock source is used.
Table 21 I/O Status in Low-Power Dissipation Modes
D0–D9
D10–D11
R0–R7
Output
Standby Mode,
Watch Mode
Stop Mode
Retained
High impedance
—
—
Retained or output
of peripheral functions
High impedance
Input
Active Mode,
Subactive Mode
Input enabled
Input enabled
Input enabled
32