English
Language : 

MN63Y1208 Datasheet, PDF (52/120 Pages) Panasonic Semiconductor – Built-in 4-Kbit FeRAM non-volatile memory with fast write and low power consumption
Chapter 4 RF Communication Mode
4.3.5 Upper Command Format
The upper commands (SELECT, READ, WRITE) are compliant with the APDU (Application Protocol Data
Unit) format of ISO/IEC7816-4.
Figure 4-18 shows the command APDU format. Table 4-16 shows the command APDU field definition. Figure
4-19 gives the response APDU format. Table 4-17 gives the response APDU field definition.
The command APDU format shown in Figure 4-18 and the response APDU format shown in Figure 4-19 are
configured in the information field INF of the ISO/IEC14443-4 block format shown in Figure 4-14.
CLA
INS
P1
P2
Lc
Data
Le
Class Instruction Param Param Lc field
Data byte
Le
byte
byte
byte
byte
(Lc bytes)
field
Figure 4-18 Command APDU Format
Field name
Class byte
Instruction byte
Param byte 1
Param byte 2
Lc field
Data byte
Le field
Table 4-16 Command APDU Field Definition
Byte length
1
1
1
1
1
n
1
Definition
Fixed to 0x00
Instruction code
Command parameter
Command parameter
If a data byte exists in the command APDU, set the
byte length of n; if not, omit the data byte.
Data block (can be omitted)
If a data byte exists in the response APDU, set the
byte length; if not, omit the data byte.
Response Body
Data byte
SW1
Status
word 1
SW2
Status
word 2
Figure 4-19 Response APDU Format
Field name
Data byte
Status word 1
Status word 2
Table 4-17 Response APDU Field Definition
Byte length
Definition
n
Data block (can be omitted)
1
Status information
1
Status information
52