Chapter 4 RF Communication Mode
4.2.5.8 Status Flag
Table 4-8 lists the meanings of status flags.
Table 4-8 Status Flag
Status flag 1 Status flag 2
Meaning
Description
0x00
0x00
Normal end
Terminated normally.
0xFF
0x50
Tunnel mode error
No response from the host
0xFF
0x51
Tunnel mode error
The host responded with an error.
0xFF
0xA1
Service count
specification error
The number of service files was out of the
specification.
0xFF
0xA2
Block count specification The number of blocks was out of the
error (*)
specification.
0xFF
0xA3
Service count
specification error
Some settings for multiple service were
different from the specification.
0xFF
0xA5
Block specification error
x Illegal access mode setting (except All-0)
x Illegal mode setting (RFU setting)
x Block number was specified outside FeRAM.
x Ascending order was not used to specify
block numbers in tunnel mode or encrypted
communication.
0xFF
0x60
Self-diagnosis error
(*)
x Write access to FeRAM-Read-Only area
(RORF setting)
x Plaintext (unencrypted) command access to
Encrypted-communication-enable-only area
(SECURITY setting)
(*) For more information about these errors, see the Administrator's Manual.