AMIS-30543 Datasheet, PDF (37/38 Pages) ON Semiconductor – Micro-Stepping Motor Driver | |||
|
◁ |
AMISâ30543
Table 15. SPI STATUS FLAGS OVERVIEW
Mnemonic
Flag
Length
(bit)
Related
SPI Register
Comment
Reset
State
CPFail Charge pump failure
1
Status Register 0 â0â = no failure
â0â
â1â = failure: indicates that the charge pump does
not reach the required voltage level. Note 1
MSP[8:0] Microâstep position
9
Status Register 3 and Translator micro step position
Status Register 4
â000000000â
OPENX OPEN Coil X
1
Status Register 0 â1â = Open coil detected
â0â
OPENY OPEN Coil Y
1
Status Register 0 â1â = Open coil detected
â0â
OVCXNB OVer Current on X
1
Status Register 1 â0â = no failure
â0â
Hâbridge; MOTXN
â1â = failure: indicates that over current is detected
terminal; Bottom
at bottom transistor XNâterminal
tran.
OVCXNT OVer Current on X
1
Status Register 1 â0â = no failure
â0â
Hâbridge; MOTXN
â1â = failure: indicates that over current is detected
terminal; Top transist.
at top transistor XNâterminal
OVCXPB OVer Current on X
1
Status Register 1 â0â = no failure
â0â
Hâbridge; MOTXP
â1â = failure: indicates that over current is detected
terminal; Bottom
at bottom transistor XPâterminal
tran.
OVCXPT OVer Current on X
1
Status Register 1 â0â = no failure
â0â
Hâbridge; MOTXP
â1â = failure: indicates that over current is detected
terminal; Top transist.
at top transistor XPâterminal
OVCYNB OVer Current on Y
1
Status Register 2 â0â = no failure
â0â
Hâbridge; MOTYN
â1â = failure: indicates that over current is detected
terminal; Bottom
at bottom transistor YNâterminal
tran.
OVCYNT OVer Current on Y
1
Status Register 2 â0â = no failure
â0â
Hâbridge; MOTYN
â1â = failure: indicates that over current is detected
terminal; Top transist.
at top transistor YNâterminal
OVCYPB OVer Current on Y
1
Status Register 2 â0â = no failure
â0â
Hâbridge; MOTYP
â1â = failure: indicates that over current is detected
terminal; Bottom
at bottom transistor YPâterminal
tran.
OVCYPT OVer Current on Y
1
Status Register 2 â0â = no failure
â0â
Hâbridge; MOTYP
â1â = failure: indicates that over current is detected
terminal; Top transist.
at top transistor YPâterminal
TSD Thermal shutdown
1
Status Register 2
â0â
TW
Thermal warning
1
Status Register 0
â0â
WD
Watchdog event
1
Status Register 0 â1â = watchdog reset after timeâout
â0â
NOTE: WD â This bit indicates that the watchdog timer has not been cleared properly. If the master reads that WD is set to â1â after reset,
it means that a watchdog reset occurred (warm boot) instead of POR (cold boot). WD bit will be cleared only when the master
writes â0â to WDEN bit.
Table 16. ORDERING INFORMATION
Part No.
Peak Current
Temperature
Range
Package
Shippingâ
AMIS30543C5431G
3000 mA
â40°C to 125°C
NQFPâ32 (7 x 7 mm)
(PbâFree)
Units / Tubes
AMIS30543C5431RG
3000 mA
â40°C to 125°C
NQFPâ32 (7 x 7 mm)
(PbâFree)
Tape & Reel
â For information on tape and reel specifications, including part orientation and tape sizes, please refer to our Tape and Reel Packaging
Specifications Brochure, BRD8011/D.
http://onsemi.com
37
|
▷ |