MC68HC12 Datasheet, PDF (341/478 Pages) Motorola, Inc – The MC68HC912DT128A microcontroller unit (MCU) is a 16-bit device composed of standard on-chip peripherals including a 16-bit central processing unit
MSCAN Controller
Low Power Modes
18.8.2 msCAN12 SOFT_RESET Mode
In SOFT_RESET mode, the msCAN12 is stopped. Registers can still be
accessed. This mode is used to initialize the module configuration, bit
timing, and the CAN message filter. See msCAN12 Module Control
Register (CMCR0) for a complete description of the SOFT_RESET
mode.
When setting the SFTRES bit, the msCAN12 immediately stops all
ongoing transmissions and receptions, potentially causing the CAN
protocol violations. The user is responsible to take care that the
msCAN12 is not active when SOFT_RESET mode is entered. The
recommended procedure is to bring the msCAN12 into SLEEP mode
before the SFTRES bit is set.
18.8.3 msCAN12 POWER_DOWN Mode
The msCAN12 is in POWER_DOWN mode when
• the CPU is in STOP mode or
• the CPU is in WAIT mode and the CSWAI bit is set (see msCAN12
Module Control Register (CMCR0)).
When entering the POWER_DOWN mode, the msCAN12 immediately
stops all ongoing transmissions and receptions, potentially causing CAN
protocol violations. The user is responsible to take care that the
msCAN12 is not active when POWER_DOWN mode is entered. The
recommended procedure is to bring the msCAN12 into SLEEP mode
before the STOP instruction (or the WAI instruction, if CSWAI is set) is
executed.
To protect the CAN bus system from fatal consequences of violations to
above rule, the msCAN12 will drive the TxCAN pin into recessive state.
In POWER_DOWN mode, no registers can be accessed.
MC68HC912DT128A — Rev 4.0
MOTOROLA
MSCAN Controller
Technical Data
341