IC-MU_17 Datasheet, PDF (32/66 Pages) IC-Haus GmbH – MAGNETIC OFF-AXIS POSITION ENCODER - POLE WIDTH 1.28MM
iC-MU MAGNETIC OFF-AXIS
POSITION ENCODER - POLE WIDTH 1.28MM
Rev D1, Page 32/66
GSSI
Code
0
1
Addr. 0x12; bit 7
Data format
binary coded
Gray coded
Table 43: Data format (for MT and ST data)
SSI interface ring operation can be activated for the
repeated output of position data in SSI protocol. In this
mode position data output is repeated cycle by cycle
separated by a zero-bit until the internal timeout ttos (p.
12) is reached. After ttos has elapsed a new request can
be made for position data. By checking the repeated
position data for equality, SSI ring operation mode en-
ables any possible transmission errors to be detected.
If RSSI is deactivated zeros are subsequently output
after the position data output.
RSSI
Code
0
1
Addr. 0x12; bit 6
Ring operation
normal output
Ring operation
Table 44: Ring operation