English
Language : 

IC-MU_17 Datasheet, PDF (11/66 Pages) IC-Haus GmbH – MAGNETIC OFF-AXIS POSITION ENCODER - POLE WIDTH 1.28MM
iC-MU MAGNETIC OFF-AXIS
POSITION ENCODER - POLE WIDTH 1.28MM
OPERATING REQUIREMENTS: I/O Interface
Item Symbol Parameter
No.
Conditions
SPI-Interface (Figure 2)
I101 TSCK
I102 tNCS
Permissible Clock Period
Setup Time:
NCS lo before SCK hi → lo
see Elec. Char. No.: 906
I103 tp1
Propagation Delay:
MISO hi after NCS lo → hi
I104 tIS
Setup Time:
MOSI stable before SCK lo → hi
I105 tSI
Hold Time:
MOSI stable after SCK lo → hi
I106 tp2
Propagation Delay:
MISO stable after SCK hi → lo
I107 tCC
Wait Time:
between NCS lo → hi and NCS hi → lo
BiSS-Interface (Figure 3,Figure 4)
I108 ttos
Timeout adaptive
typ. tinit
I109 tMAS
Permissible Clock Period
I110 tMASh
Clock Signal Hi Level Duration
I111 tMASl
Clock Signal Lo Level Duration
SSI-Interface (Figure 5, Figure 6)
I112 ttos
Timeout adaptive
typ. tinit
I113
I114
I115
tMAS
tMASh
tMASl
Permissible Clock Period
Clock Signal Hi Level Duration
Clock Signal Lo Level Duration
Timing SPI
PA0: NCS
tNCS
PA1: SCK
PA2: MOSI
PA3: MISO
tIS
tSI
TSCK
tp2
Figure 2: Timing SPI interface
Timing BiSS
PA1:MA
PA3:SLO
t
MAS
START DATA
DATA
tt
MASh MASl
t
tos
t
tos
Figure 3: Timing BiSS interface
Rev D1, Page 11/66
Min.
Unit
Max.
1/f()
ns
50
ns
30
ns
30
ns
30
ns
30
ns
500
ns
1.5*tMAS 1.5*tMAS + ns
3*2/fosc
100
2 x ttos
ns
50
ttos
ns
50
ns
1.5*tMAS 1.5*tMAS +
3*2/fosc
250
2 x ttos
ns
125
ttos
ns
125
ns
tCC
tp1