IC-MU_13 Datasheet, PDF (29/59 Pages) IC-Haus GmbH – OFF-AXIS NONIUS ENCODER WITH INTEGRATED HALL SENSORS | |||
|
◁ |
iC-MU OFF-AXIS NONIUS ENCODER
WITH INTEGRATED HALL SENSORS
preliminary
SSI interface
Rev B1, Page 29/59
ERR
out
cyle
Figure 14: Example of SSI line signals (MODEA=0x5/0x6) with optional unidirectional register communica-
tion
LSB
ERR WRN MSB
LSB
Zero bits
CRC
out
cycle
Figure 15: Example of extended SSI line signals (MODEA=0x7, ExtSSI)
MODEA
Code
0x4
0x5
0x6
0x7
Description
Standard SSI, no error-bit
Standard SSI, error-bit low active
Standard SSI, error-bit high active
extended SSI, data-package like BiSS-C
Table 38: MODEA: SSI
In standard SSI mode singleturn data and, optionally,
multiturn data, an error, and a stop zero can be trans-
mitted. In extended SSI mode (ExtSSI) the multiturn
data (optional), singleturn data, error, warning, and
CRC can be read out. All data is sent with the MSB
ï¬rst and is equivalent to the data package that is out-
put through BiSS.
The SSI interface of iC-MU can handle sensor data
communication and unidirectional register communica-
tion (Advanced SSI protocoll see Figure 14).
In SSI mode the sensor data can be output in binary
or Gray code.
|
▷ |