English
Language : 

IC-MU_13 Datasheet, PDF (25/59 Pages) IC-Haus GmbH – OFF-AXIS NONIUS ENCODER WITH INTEGRATED HALL SENSORS
iC-MU OFF-AXIS NONIUS ENCODER
WITH INTEGRATED HALL SENSORS
preliminary
CONFIGURABLE I/O INTERFACE
Rev B1, Page 25/59
Setting the interfaces
iC-MU has several configurable output modes which
can be set using parameters MODEA and MODEB.
The pins at port A are set with MODEA. The choice
of a serial interface at port A has also effect on the out-
put of error and warning bits in the serial protocol see
Table 31.
N.B.:
With an empty EEPROM or after the third faulty at-
tempt to read-in the configuration data from the EEP-
ROM the default value of MODEA is set to BiSS or
SPI depending on the logic level at pin PA0 (PA0=0
→ BiSS, PA0=1 → SPI).
MODEA(2:0)
Addr. 0x0B; bit 2:0
Code PA0
PA1
PA2
PA3
Function
0x0
NCS SCLK MOSI MISO SPITRI
0x1
NCS SCLK MOSI MISO SPI
0x2
NPRES MA
SLI
SLO BiSS
0x3
NPRES A
B
Z
ABZ *)
0x4
NPRES MA
SLI
SLO SSI
0x5
NPRES MA
SLI
SLO SSI+ERRL
0x6
NPRES MA
SLI
SLO SSI+ERRH
0x7
NPRES MA
SLI
SLO ExtSSI
Note: *) to save this configuration in the EEPROM see command
SWITCH page 52 ff.
Table 28: Port A configuration
The pins at port B are set with MODEB.
MODEB(2:0)
Code PB0
0x0
A
0x1
U
0x2
STEP
0x3
CW
Addr. 0x0B; bit 6:4
PB1
PB2
PB3
B
Z
NER
V
W
NER
DIR
NCLR NER
CCW NCLR NER
0x4
NSN PSN PCN NCN
0x5
NSM PSM PCM NCM
0x6
-
-
-
-
0x7
-
-
-
-
Function
ABZ
UVW
Step/Direction
CW/CCW
Incremental
SIN/COS
Nonius
SIN/COS
Master
reserved
tristate
Table 29: Port B configuration
N.B.:
It is not possible to select ABZ at port A and ABZ,
Step/Direction or CW/CCW at port B simultaneously.
In operating modes ABZ, UVW, step/direction, and
CW/CCW the position is output incrementally. In set-
ting SIN/COS Master the master track analog signal is
switched directly to the analog drivers. The signals of
the nonius track are available on the drivers with set-
ting SIN/COS Nonius.