English
Language : 

MC3610 Datasheet, PDF (53/67 Pages) List of Unclassifed Manufacturers – Axis Accelerometer
MC3610 3-Axis Accelerometer
Preliminary Datasheet
8.17 (0x22) Drive Motion Z Register
This register controls the test mode which moves the sensor in the Z axis direction.
Bit
Addr
Name
POR Value R/W
7
6
5
4
3
2
1
0
0x22
DMZ
RESV
RESV
RESV
RESV
DNZ
DPZ
RESV
RESV 00000000 RW
Software must always write 0 to bits [7:4] and [1:0].
Bit
Name
Description
[1:0]
RESV
Reserved. Always write 0 to these bits.
2
DPZ
0: Disabled (default)
1: Move the sensor in Z Positive direction
3
DNZ
0: Disabled (default)
1: Move the sensor in Z Negative direction
[7:4]
RESV
Reserved. Always write 0 to these bits.
Table 27. Drive Motion Z Register Settings
mCube Proprietary.
APS-048-0042v1.6
© 2015 mCube Inc. All rights reserved.
53 / 67