LM3S8730 Microcontroller
Bit/Field
2
1
0
Name
SIE
IE
INIT
Type
R/W
R/W
R/W
Reset
0
0
1
Description
Status Change Interrupt Enable
0: Disabled. No Status Change interrupt is generated.
1: Enabled. An interrupt is generated when a message has successfully
been transmitted or received, or a CAN bus error has been detected. A
change in the TxOk or RxOk bits in the CANSTS register generates an
interrupt.
CAN Interrupt Enable
0: Interrupt disabled.
1: Interrupt enabled.
Initialization
0: Normal operation.
1: Initialization started.