English
Language : 

EPF8452ATC100-4N Datasheet, PDF (30/62 Pages) Altera Corporation – Programmable Logic Device Family
FLEX 8000 Programmable Logic Device Family Data Sheet
Table 15. FLEX 8000 3.3-V Device DC Operating Conditions Note (4)
Symbol
Parameter
Conditions
V IH
V IL
V OH
V OL
II
IOZ
I CC0
High-level input voltage
Low-level input voltage
High-level output voltage
I OH = –0.1 mA DC (5)
Low-level output voltage
I OL = 4 mA DC (5)
Input leakage current
VI = V CC or ground
Tri-state output off-state current VO = VCC or ground
VCC supply current (standby) VI = ground, no load (6)
Min Typ Max Unit
2.0
–0.3
VCC + 0.3 V
0.8
V
VCC – 0.2
V
0.45
V
–10
10
µA
–40
40
µA
0.3
10
mA
Table 16. FLEX 8000 3.3-V Device Capacitance Note (7)
Symbol
Parameter
Conditions
Min Max Unit
C IN
C OUT
Input capacitance
Output capacitance
VIN = 0 V, f = 1.0 MHz
VOUT = 0 V, f = 1.0 MHz
10
pF
10
pF
Notes to tables:
(1) See the Operating Requirements for Altera Devices Data Sheet.
(2) Minimum DC input voltage is –0.3 V. During transitions, the inputs may undershoot to –2.0 V or overshoot to 5.3 V
for input currents less than 100 mA and periods shorter than 20 ns.
(3) The maximum VCC rise time is 100 ms. VCC must rise monotonically.
(4) These values are specified in Table 14 on page 29.
(5) The IOH parameter refers to high-level TTL output current; the IOL parameter refers to low-level TTL output current.
(6) Typical values are for TA = 25° C and VCC = 3.3 V.
(7) Capacitance is sample-tested only.
Figure 16 shows the typical output drive characteristics of 5.0-V
FLEX 8000 devices. The output driver is compliant with PCI Local Bus
Specification, Revision 2.2.
30
Altera Corporation