W83L951DG/W83L951FG
6.15 Real Time Clock Generator Block
Base on 32.768KHz, Real Time Clock Generator Block finishes counts which include seconds,
minutes, and hours automatically. It also provides alarm function.
When {RTCHR, RTCMIN, RTCSEC} and {RTCHRAL, RTCMINAL, RTCSECAL} are equal, interrupt
will occur to Microprocessor automatically.
Table 6-24.Real Time Clock Generator Register Define
REAL TIME CLOCK BLOCK(6)
EXTADDR
NAME
7
6
5
4
3
2
1
0
70
RTCSEC
RTC Seconds Register[7:0]
71
RTCSECAL
RTC Seconds Alarm Register[7:0]
72
RTCMIN
RTC Minutes Register[7:0]
73
RTCMINAL
RTC Minutes Alarm Register[7:0]
74
RTCHR
RTC Hours Register[7:0]
75
RTCHRAL
RTC Hours Alarm Register[7:0]
Note:
Gray: Only with System Reset to initial.
RTCSEC, RTCMIN, RTCHR should initial after local reset.
6.15.1 Register Description
6.15.1.1 RTC Second Register (RTCSEC) (Default Value: 0000_0000)
Read: Indicate RTC second value at present.
Write: Set RTC second value at present.
6.15.1.2 RTC Second Alarm Register (RTCSECAL) (Default Value: 0000_0000)
Read: Indicate RTC second alarm at present.
Write: Set RTC second alarm value at present.
6.15.1.3 RTC Minute Register (RTCMIN) (Default Value: 0000_0000)
Read: Indicate RTC minute value at present.
Write: Set RTC minute value at present.