This state is identical to "F3 Deactivated without clock" except the internal clocks are enabled. The state is entered by the ECK
command. The clocks are enabled approximately 0.5 ms to 4 ms after the ECK command, depending on the crystal capacitances.
(It is about 0.5 ms for 12pF to 33pF capacitance).
F3Awaiting Deactivation
The W66910 enters this state after receiving INFO 0 (in states F5 to F8) for 16ms (64 frames). This time constant prevents
spurious effect on S interface. Any non-INFO 0 signal on the S interface causes transition to "F5 Identifying Input" state. If this
transition does not occur in a specific time (500 - 1000 ms), the microprocessor may issue DRC or ECK command to deactivate
layer 1.
F4Awaiting Signal
This state is reached when an activate request command has been received. In this state, the layer 1 transmits INFO1 and INFO 0
is received from the S interface. The software starts timer T3 of I.430 when issuing activate request command. The software
deactivates layer 1 if no signal other than INFO 0 has been received on S interface before expiration of T3.
F5Identifying Input
After the receipt of any non-INFO 0 signal from NT, the W66910 ceases to transmit INFO 1 and awaits identification of INFO 2
or INFO 4. This state is reached at most 50 µs after a signal different from INFO 0 is present at the receiver of the S interface.
F6 Synchronized
When W66910 receives an activation signal (INFO 2), it responds with INFO 3 and waits for normal frames (INFO 4). This state
is reached at most 6 ms after an INFO 2 arrives at the S interface (in case the clocks were disabled in "F3 Deactivated without
clock").
F7 Activated
This is the normal active state with the layer 1 protocol activated in both directions. From state "F6 Synchronized" , state F7 is
reached at most 0.5 ms after reception of INFO 4. From state "F3 Deactivated without clock" with the clocks disabled, state F7 is
reached at most 6 ms after the W66910 is directly activated by INFO 4.
F8Lost Framing
This is the state where the W66910 has lost frame synchronization and is awaiting resynchronization by INFO 2 or INFO 4 or
deactivation by INFO 0.
Special States:
Analog Loop Initiated
On Enable Analog Loop command, INFO 3 is sent by the line transmitter internally to the line receiver (INFO 0 is sent to the
line). The receiver is not yet synchronized.
Analog Loop Activated
The receiver is synchronized on INFO 3 which is looped back internally from the transmitter. The indication 'TI" or "ATI" is sent
depending on whether or not a signal different from INFO 0 is detected on the S interface.
Send Continuous Pulses
A 96 kHz continuous pulse with alternating polarities is sent.