English
Language : 

W66910 Datasheet, PDF (20/81 Pages) Winbond – TE Mode ISDN S/T-Controller with Microprocessor Interface
Data Sheet
W66910 PCI ISDN S/T-Controller
After hardware reset, the receiver may enter power down state in order to save power consumption. In this state, the internal
clocks are turned off, but the analog level detector is still active to detect signal coming from the S interface. The power down
state is left either by non-INFO 0 signal from S interface or C/I command from microprocessor.
7.2.2 Receiver Clock Recovery And Timing Generation
A Digital Phase Locked Loop (DPLL) circuit is used to derive the receive clock from the received data stream. This DPLL uses a
7.68 MHz clock as reference. According to I.430, the transmit clock is normally delayed by 2 bit time from the receive clock. The
"total phase deviation from input to output" is -7% to +15% of a bit period. In some cases, delay compensation may be needed to
meet this requirement (see OPS1-0 bits in D_CTL register).
TABLE 7.1 OUTPUT PHASE DELAY COMPENSATION TABLE
OPS1
0
0
1
1
OPS0
0
1
0
1
Effect
No phase delay compensation
Phase delay compensation 260 ns
Phase delay compensation 520 ns
Phase delay compensation 1040 ns
W66910 does not need RC filter on receiver side, therefore zero delay compensation is selected normally. This is also the default
setting.
The PCM output clocks (PFCK1-2, PBCK) are locked to the S-interface timing with jitter. See the electrical specification.
7.2.3 Layer 1 Activation/Deactivation
The layer 1 activation/deactivation procedures are implemented by a finite state machine according to I.430 TE mode. The state
transitions are triggered by signals received at S interface or commands issued from microprocessor. The state machine outputs
signal to S interface and indication to microprocessor. The CIX register is used by microprocessor to issue command, and the
CIR register is used by microprocessor to receive indication.
Some commands are used for special purposes. They are "layer 1 reset", "analog loopback", "send continuous zeros" and "send
single zero".
7.2.3.1 States Descriptions And Command/Indication Codes
F3Deactivatedwithout clock
This is the "deactivated" state of ITU-T I.430. The receive line awake unit is active except during a hardware reset pulse. After
reset, once the indication "1111" has been read out, internal clocks will turn off and stay at this state if INFO 0 is received on the
S line. The turn off time is approximate 93 ms. The ECK command must be issued to activate the clocks.
F3Deactivatedwith clock
-20 -
Publication Release Date: Feb,2001