English
Language : 

MSP430FG439 Datasheet, PDF (21/88 Pages) Texas Instruments – Mixed-Signal Microcontrollers
www.ti.com
MSP430FG439, MSP430FG438, MSP430FG437
SLAS380D – APRIL 2004 – REVISED NOVEMBER 2014
5.16 Power-On Reset (POR) and Brownout Reset (BOR)(1)
over recommended operating free-air temperature range (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TYP MAX UNIT
td(BOR)
VCC(start)
V(B_IT–)
Brownout (2)
dVCC/dt ≤ 3 V/s (see Figure 5-10)
dVCC/dt ≤ 3 V/s (see Figure 5-10 through
Figure 5-12)
2000 µs
0.7 × V(B_IT– )
V
1.71 V
Vhys(B_IT–)
t(reset)
dVCC/dt ≤ 3 V/s (see Figure 5-10)
70
Pulse length needed at RST/NMI pin to accepted
reset internally, VCC = 2.2 V, 3 V
2
130
210 mV
µs
(1) The current consumption of the brownout module is already included in the ICC current consumption data. The voltage level V(B_IT–) +
Vhys(B_IT–) is ≤ 1.8 V.
(2) During power up, the CPU begins code execution following a period of td(BOR) after VCC = V(B_IT–) + Vhys(B_IT–). The default FLL+ settings
must not be changed until VCC ≥ VCC(min), where VCC(min) is the minimum supply voltage for the desired operating frequency. See the
MSP430x4xx Family User's Guide (SLAU056) for more information on the brownout/SVS circuit.
VCC
Vhys(B_IT-)
V(B_IT-)
VCC(start)
1
0
2
VCC = 3 V
Typical Conditions
1.5
td(BOR)
Figure 5-10. POR and BOR vs Supply Voltage
V CC
tpw
3V
1
V CC(drop)
0.5
0
0.001
1
tpw - Pulse Width - m s
1000
1 ns
1 ns
tpw - Pulse Width - ms
Figure 5-11. VCC(drop) Level with a Square Voltage Drop to Generate a POR or BOR Signal
Copyright © 2004–2014, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: MSP430FG439 MSP430FG438 MSP430FG437
Specifications
21