English
Language : 

MSP430FG439 Datasheet, PDF (15/88 Pages) Texas Instruments – Mixed-Signal Microcontrollers
www.ti.com
MSP430FG439, MSP430FG438, MSP430FG437
SLAS380D – APRIL 2004 – REVISED NOVEMBER 2014
5.5 Schmitt-Trigger Inputs – Ports P1 to P6, RST/NMI, JTAG (TCK, TMS, TDI/TCLK, TDO/TDI)
over recommended operating free-air temperature range (unless otherwise noted)
PARAMETER
VIT+ Positive-going input threshold voltage
VCC
2.2 V
3V
MIN MAX UNIT
1.1 1.55
V
1.5 1.98
VIT– Negative-going input threshold voltage
2.2 V
3V
0.4 0.9
V
0.9 1.3
Vhys Input voltage hysteresis (VIT+ – VIT– )
2.2 V
3V
0.3 1.1
V
0.5
1
5.6 Inputs Px.y, TAx, TBx
over recommended operating free-air temperature range (unless otherwise noted)
PARAMETER
t(int)
External interrupt timing
TEST CONDITIONS
Port P1, P2: P1.x to P2.x, external trigger signal
for the interrupt flag(1)
VCC
2.2 V
3V
MIN MAX UNIT
62
ns
50
t(cap)
Timer_A or Timer_B capture timing
TA0, TA1, TA2
TB0, TB1, TB2
2.2 V
62
ns
3V
50
f(TAext)
f(TBext)
f(TAint)
f(TBint)
Timer_A or Timer_B clock
frequency externally applied to pin
TACLK, TBCLK, INCLK: t(H) = t(L)
Timer_A or Timer_B clock
frequency
SMCLK or ACLK signal selected
2.2 V
3V
2.2 V
3V
8
MHz
10
8
MHz
10
(1) The external signal sets the interrupt flag every time the minimum t(int) parameters are met. It might be set with trigger signals shorter
than t(int).
5.7 Leakage Current – Ports P1 to P6(1)
over recommended operating free-air temperature range (unless otherwise noted)
Ilkg(Px.y)
PARAMETER
Leakage current, Port Px
V(Px.y) (2)
TEST CONDITIONS
VCC = 2.2 V, 3 V
(1) The leakage current is measured with VSS or VCC applied to the corresponding pins, unless otherwise noted.
(2) The port pin must be selected as input.
MIN MAX UNIT
±50 nA
Copyright © 2004–2014, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: MSP430FG439 MSP430FG438 MSP430FG437