English
Language : 

LP3918 Datasheet, PDF (13/39 Pages) National Semiconductor (TI) – Battery Charge Management and Regulator Unit
LP3918
www.ti.com
SNVS476D – AUGUST 2007 – REVISED MAY 2013
Serial Interface
Unless otherwise noted, VIN ( = VIN1 = VIN2 = BATT) = 3.6V, GND = 0V, CVIN1-2=10µF, CLDOX=1µF, and VLDO2 (DIG) = 3.0V.
Typical values and limits appearing in normal type apply for TJ = 25°C. Limits appearing in boldface type apply over the
entire junction temperature range for operation, Ta = TJ = −40°C to +125°C. (1)(2)
Symbol
Parameter
Condition
Limit
Typ
Units
Min
Max
fCLK
Clock Frequency
tBF
Bus-Free Time between
START and STOP
400
kHz
1.3
µs
tHOLD
Hold Time Repeated START
Condition
0.6
µs
tCLK-LP
tCLK-HP
tSU
CLK Low Period
CLK High Period
Set-Up Time Repeated
START Condition
1.3
µs
0.6
µs
0.6
µs
tDATA-HOLD
tDATA-SU
tSU
Data Hold Time
Data Set-Up Time
Set-Up Time for STOP
Condition
50
ns
100
ns
0.6
µs
tTRANS
Maximum Pulse Width of
50
ns
Spikes that Must be
Suppressed by the Input
Filter of both DATA & CLK
Signals
(1) All electrical characteristics having room-temperature limits are tested during production with TJ = 25°C. All hot and cold limits are
speficied by correlating the electrical characteristics to process and temperature variations and applying statistical process control.
(2) Specified by design. Not production tested.
Copyright © 2007–2013, Texas Instruments Incorporated
Product Folder Links: LP3918
Submit Documentation Feedback
13