Table 13. General Switching Characteristics, RX BB LVDS Output – DDR0
PARAMETER
BASEBAND INTERFACE DDR LVDS
fCLK(Byte)
fCLK(Nibble0)
fCLK(Nibble1)
fCLK(Serial)
tskmax(BB)Serial0
Baseband output clock frequency
BBOUT3 Clk, BBOUT1:0 Data, BBOUT2
Sync
tskmin(BB)Serial0
BBOUT3 Clk, BBOUT1:0 Data, BBOUT2
Sync
tskmax(BB)Serial1
BBOUT3 Ck, BBOUT1:0 Data, BBOUT2
Sync
tskmin(BB)Serial1
BBOUT3 Clk, BBOUT1:0 Data, BBOUT2
Sync
tskmax(BB)Serial2
BBOUT7 Clk, BBOUT5:4 Data, BBOUT6
Sync
tskmin(BB)Serial2
BBOUT7 Clk, BBOUT5:4 Data, BBOUT6
Sync
tskmax(BB)Nibble0
BBOUT3 Clk, BBOUT5,4,1,0 Data, BBOUT2
Sync
tskmin(BB)Nibble0
BBOUT3 Clk, BBOUT5,4,1,0 Data, BBOUT2
Sync
tskmax(BB)Nibble1
BBOUT7 Clk, BBOUT11:8 Data, BBOUT6
Sync
tskmin(BB)Nibble1
BBOUT7 Clk, BBOUT11:8 Data, BBOUT6
Sync
tskmax(BB)Byte
BBOUT7 Clk, BBOUT11:8,5:4,2:0 Data,
BBOUT6 Sync
tskmin(BB)Byte
BBOUT7 Clk, BBOUT11:8,5:4,2:0 Data,
BBOUT6 Sync
TEST CONDITIONS
See (1)
See (2) (3)
See (2) (3) (4)
See (2) (3)
See (2) (3) (4)
See (5) (6)
See (5) (6) (7)
See (5) (6)
See (5) (6) (7)
See (5) (6)
See (5) (6) (7)
See (5) (6)
See (5) (6) (7)
MIN NOM MAX UNIT
–60
400
–130
500
–45
425
0
400
10
460
0
480
384 MHz
384 MHz
500 MHz
384 MHz
ps
ps
ps
ps
ps
ps
ps
ps
ps
ps
ps
ps
(1) Chip specifications are production tested at 90°C case temperature for the given specification. Early production lots are sample tested
at –40°C.
(2) Skew measured for RX BBOUT data and frame signals, relative to the BBclk signal at zero crossing. BBclk is measured at threshold
crossing. Lab measurement +signal → 50 Ω → Vcommon → 50 Ω → –signal. Vcommon has a 0.01-µF filter capacitor to GND.
Differential probe used for measurement.
(3) The customer interface design modifies the trace lengths based on the desired receiver timing and clock delays.
(4) tsu = –tskmax; thold = 1/4 BBclk period – tskmin.
(5) Skew measured for RX BBOUT data and frame signals, relative to the BBclk signal at zero crossing. BBclk is measured at threshold
crossing. Lab measurement +signal → 50 Ω → Vcommon → 50 Ω → –signal. Vcommon has a 0.01-µF filter capacitor to GND.
Differential probe used for measurement.
(6) The customer interface design modifies the trace lengths based on the desired receiver timing and clock delays.
(7) tsu = –tskmax; thold = 1/4 BBclk period – tskmin.
© 2010–2011, Texas Instruments Incorporated