English
Language : 

LSM303AH Datasheet, PDF (70/82 Pages) –
Register description
LSM303AH
8.40 CFG_REG_B_M (61h)
Table 99. CFG_REG_B_M register
0
0
OFF_
0
CANC_
ONE_
INT_on_
DataOFF
Set_FREQ
OFF_CANC
LPF
SHOT
OFF_CANC_
ONE_SHOT
INT_on_
DataOFF
Set_FREQ
OFF_CANC
LPF
Table 100. CFG_REG_B_M register description
Enables offset cancellation in single measurement mode. The OFF_CANC bit
must be set to 1 when enabling offset cancellation in single measurement mode.
0: offset cancellation in single measurement mode disabled;
1: offset cancellation in single measurement mode enabled.
If ‘1’, the interrupt block recognition checks data after the hard-iron correction to
discover the interrupt.
Selects the frequency of the set pulse.
0: set pulse is released every 63 ODR;
1: set pulse is released only at power-on after PD condition.
Enables offset cancellation.
Low-pass filter enable (see Table 101)
0: digital filter disabled; 1: digital filter enabled
Table 101. Digital low-pass filter
CFG_REG_B[LPF]
BW [Hz]
0 (disable)
ODR/2
1 (enable)
ODR/4
70/82
DocID027766 Rev 6