English
Language : 

LSM303AH Datasheet, PDF (57/82 Pages) –
LSM303AH
Register description
8.9
OUT_T_A (26h)
Temperature output register (r).
TEMP7
TEMP6
Table 48. OUT_T_A register
TEMP5 TEMP4 TEMP3 TEMP2
TEMP1
TEMP0
Temp [7:0]
Table 49. OUT_T_A register description
Temperature sensor output data.
The value is expressed as two’s complement sign. Sensitivity = 1 °C/LSB
0 LSB represents T=25 °C ambient.
8.10
STATUS_A (27h)
Status register (r)
FIFO_THS WU_IA
Table 50. STATUS_A register
SLEEP_ DOUBLE_ SINGLE_
STATE
TAP
TAP
6D_IA
FF_IA
DRDY
Table 51. STATUS_A register description
FIFO_THS
FIFO threshold status flag.
(0: FIFO filling is lower than threshold level; 1: FIFO filling is equal to or higher than the
threshold level.)
WU_IA
Wakeup event detection status.
(0: WU event not detected; 1: Wakeup event detected)
SLEEP_
STATE
Sleep event status.
(0: Sleep event not detected; 1: Sleep event detected)
DOUBLE_ Double-tap event status
TAP
(0: Double-tap event not detected; 1: Double-tap event detected)
SINGLE_ Single-tap event status
TAP
(0: Single-tap event not detected; 1: Single-tap event detected)
6D_IA
Source of change in position portrait/landscape/face-up/face-down.
(0: no event detected; 1: a change in position detected)
FF_IA
Free-fall event detection status.
(0: free-fall event not detected; 1: free-fall event detected)
DRDY
Data-ready status.
(0: not ready; 1: X-, Y- and Z-axis new data available)
DocID027766 Rev 6
57/82
82