English
Language : 

LSM303AH Datasheet, PDF (61/82 Pages) –
LSM303AH
Register description
8.21
INT_DUR_A (32h)
Interrupt duration register (r/w)
LAT3
LAT2
Table 66. INT_DUR_A register
LAT1
LAT0
QUIET1 QUIET0 SHOCK1 SHOCK0
LAT [3:1]
QUIET [1:0]
SHOCK [4:0]
Table 67. INT_DUR_A register description
Duration of maximum time gap for double-tap recognition. When double-tap
recognition is enabled, this register expresses the maximum time between two
successive detected taps to determine a double-tap event.
1 LSB = 32 TODR.
Expected quiet time after a tap detection: this register represents the time after
the first detected tap in which there must not be any over-threshold event.
1 LSB = 4 TODR.
Maximum duration of over-threshold event: this register represents the maximum
time of an over-threshold signal detection to be recognized as a tap event.
1 LSB = 8 TODR
8.22
WAKE_UP_THS_A (33h)
Wakeup threshold register (r/w)
SINGLE_
DOUBLE_
TAP
SLEEP_
ON
Table 68. WAKE_UP_THS_A register
WU_
THS_ 5
WU_
THS_4
WU_
THS_3
WU_
THS 2
WU_
THS 1
WU_
THS 0
SINGLE_
DOUBLE_
TAP
SLEEP_ON
WU_THS [5:0]
Table 69. WAKE_UP_THS_A register description
Double/single-tap event detection:
(0: double-tap event detection; 1: single-tap event detection)
Sleep (inactivity) enable
(0: sleep disabled; 1: sleep enabled)
Wakeup threshold
DocID027766 Rev 6
61/82
82