English
Language : 

PD72042B_15 Datasheet, PDF (86/92 Pages) Renesas Technology Corp – LSI DEVICE FOR Inter Equipment BusTM (IEBusTM) PROTOCOL CONTROL
Oscillator circuit (External system clock)
X1 XO GND
C1 C2
µPD72042B
Caution When using system clock oscillator, wire the portion enclosed in broken lines in the figure as
follows to avoid adverse influences on the wiring capacitance:
• Keep the wiring length as short as possible.
• Do not cross the wiring over the other signal lines.
• Do not route the wiring in the vicinity of lines through which a high fluctuating current flows.
• Always keep the ground point of the capacitor of the oscillator circuit at the same potential
as GND.
• Do not connect the power source pattern through which a high current flows.
• Do not extract signals from the oscillator.
IEBus DRIVER/RECEIVER CHARACTERISTICS (TA = –40 to +85 °C, VDD = 5 V ±10 %)
Parameter
Symbol
Conditions
Min. Typ. Max. Unit
Output high voltage
ION
RL = 60 Ω ±5 %, R = 180 Ω ±5 %
2.73
6.22 mA
Output low voltage
IOL
1.0 µA
Common mode output voltage
VOCOM
For high and low levels
X – 1/2VDD X +
V
X = 1/2VDD 0.25
0.25
Input high voltage
VIH
120
mV
Input low voltage
VIL
20.0 mV
Input hysteresis voltage
VIHYS
25
mV
Common mode input voltage, high VIHCOM
1.00
VDD
V
– 1.0
Common mode input voltage, low VILCOM
0
VDD
V
Driver output resistance
RO
Driver output capacitance
CO
Receiver input capacitance
CI
Between BUS+ and BUS–
100
Between BUS+ and BUS–, between BUS+
and GND, and between BUS– and GND
kΩ
25 pF
25 pF
84
Data Sheet S13990EJ3V0DS