5. Electrical Characteristics
5.3.4
Control Signal Timing
Table 5.29 Control Signal Timing
Conditions: VCC = AVCC0 = VCC_USB = 1.8 to 3.6 V, VSS = AVSS0 = VSS_USB = 0 V, Ta = –40 to +105°C
Item
Symbol
Min.
Typ. Max. Unit
Test Conditions
NMI pulse
width
IRQ pulse
width
tNMIW
200
tPcyc × 2*1
—
—
ns NMI digital filter disabled
—
—
(NMIFLTE.NFLTEN = 0)
200
—
—
tNMICK × 3.5*2
—
—
NMI digital filter enabled
(NMIFLTE.NFLTEN = 1)
tIRQW
200
tPcyc × 2*1
—
—
ns IRQ digital filter disabled
—
—
(IRQFLTE0.FLTENi = 0)
200
—
—
tIRQCK × 3.5*3
—
—
IRQ digital filter enabled
(IRQFLTE0.FLTENi = 1)
tPcyc × 2 ≤ 200 ns
tPcyc × 2 > 200 ns
tNMICK × 3 ≤ 200 ns
tNMICK × 3 > 200 ns
tPcyc × 2 ≤ 200 ns
tPcyc × 2 > 200 ns
tIRQCK × 3 ≤ 200 ns
tIRQCK × 3 > 200 ns
Note:
Note 1.
Note 2.
Note 3.
200 ns minimum in software standby mode.
tPcyc indicates the cycle of PCLKB.
tNMICK indicates the cycle of the NMI digital filter sampling clock.
tIRQCK indicates the cycle of the IRQi digital filter sampling clock (i = 0 to 7).
NMI
tNMIW
Figure 5.31 NMI Interrupt Input Timing
IRQ
tIRQW
Figure 5.32 IRQ Interrupt Input Timing