English
Language : 

PD70F3826_15 Datasheet, PDF (40/75 Pages) Renesas Technology Corp – RENESAS MCU
μ PD70F3826, 70F3827, 70F3828, 70F3829, 70F3830, 70F3831, 70F3832, 70F3833, 70F3834, 70F3835, 70F3836, 70F3837 10. MOTOR CONTROL FUNCTION
The following figure shows the configuration of motor control function.
TAB1
• Carrier
• 3-phase PWM
generation
TAA4
• A/D trigger timing
generation in
tuning operation
with TAB1
TAB option
• 6-phase PWM
generation with
dead time from
3-phase PWM
• Culling control
• A/D trigger selection
TAA1
• PWM generation
High-impedance
output
controller
INTC
• Interrupt control
Crest interrupt
(INTTAB1CC0)
Valley interrupt
(INTTAB1OV)
Edge detection
Edge detection
TOAB10
TOAB1T1
TOAB1B1
TOAB1T2
TOAB1B2
TOAB1T3
TOAB1B3
TOAA11
Noise elimination
Noise elimination
INTP18/TOAB1OFF
INTP06/TOAA1OFF
A/D trigger of A/D converter
R01DS0029EJ0001 Rev.0.01
Sep 30, 2010
Page 40 of 75