English
Language : 

CLRC632 Datasheet, PDF (45/163 Pages) NXP Semiconductors – Multiple Protocol Contactless Reader IC
Philips Semiconductors
Multiple Protocol Contactless Reader IC
5.2.4.3 DecoderControl Register
Controls decoder behaviour.
Name: DecoderControl
Address: 0x1A
Product Specification Rev. 3.0; May 2003
CL RC632
Reset value: 00001000, 0x08
Access
Rights
7
6
5
0
RxMultiple ZeroAfter
Coll
r/w
r/w
r/w
4
3
RxFraming
r/w
r/w
2
RxInvert
r/w
1
0
0
RxCoding
r/w
r/w
Description of the bits
Bit
Symbol
Function
7
0
These values shall not be changed
6
RxMultiple
If set to 0, after receiving of the Frame the receiver is deactivated
If set to 1, it is possible to receive more than one Frame
5
ZeroAfter Coll If set to 1, any bits received after a bit-collision are masked to zero. This eases
resolving the anti-collision procedure defined in ISO14443-A.
4-3
RxFraming 00: for I•CODE1
01: MIFARE®, ISO14443A
10: ISO 15693
11: ISO14443B
2
RxInvert
If set to 0, a modulation at the first half bit results a logic 1 (according I•CODE1)
If set to 1, a modulation at the first half bit results a logic 0 (according ISO15693)
1
0
These values shall not be changed
0
RxCoding
0:
Manchester Coding
1:
BPSK Coding
45
Confidential