English
Language : 

AMIS-49587 Datasheet, PDF (9/59 Pages) ON Semiconductor – Power Line Carrier Modem
AMIS−49587
Table 13. POWER−ON−RESET (POR)
Parameter
Test Conditions
POR threshold
Power supply rise time
0 V to 3 V
Table 14. DIGITAL OUTPUTS: TDO, CLK_OUT
Parameter
Test Conditions
Low output voltage
IXOUT = 4 mA
High output voltage
IXOUT = −4 mA
Symbol
Min
Typ
Max
Unit
VPOR
1.7
TRPOR
1
2.7
V
ms
Symbol
Min
Typ
VOL
VOH
0.85 VDD
Max
Unit
0.4
V
V
Table 15. DIGITAL OUTPUTS WITH OPEN DRAIN: TX_END, TXD
Parameter
Test Conditions
Symbol
Min
Typ
Max
Unit
Low output voltage
IXOUT = 4 mA
VOL
0.4
V
Table 16. DIGITAL INPUTS: BR0, BR1
Parameter
Test Conditions
Low input level
High input level
0 V to 3 V
Input leakage current
Symbol
Min
Typ
Max
Unit
VIL
0.2 VDD
V
VIH
0.8 VDD
V
ILEAK
−10
10
mA
Table 17. DIGITAL INPUTS WITH PULL DOWN: TDI, TMS, TCK, TRSTB, TEST
Parameter
Test Conditions
Symbol
Min
Typ
Max
Unit
Low input level
VIL
0.2 VDD
V
High input level
VIH
0.8 VDD
V
Pull down resistor
(Note 14)
RPU
7
50
kW
14. Measured around a bias point of VDD/2.
Table 18. DIGITAL SCHMITT TRIGGER INPUTS: RXC, RESB
Parameter
Rising threshold level
Test Conditions
Falling threshold level
Input leakage current
Symbol
Min
Typ
Max
Unit
VT+
2.5
V
VT−
0.9
V
ILEAK
−10
1−
mA
Table 19. DIGITAL INPUT/OUTPUTS OPEN DRAIN: IO0, IO1, IO2
Parameter
Test Conditions
Symbol
Min
Typ
Max
Unit
Low output voltage
ICOUT = 4 mA
VOL
0.4
V
Low input level
VIL
0.2 VDD
V
High input level
VIH
0.8 VDD
V
Input leakage current
ILEAK
−10
10
mA
http://onsemi.com
9