Status Message in NOT SET MODE:
Table 25. STATUS MESSAGE IN NOT SET MODE
Byte
1
2
3
4
Where:
Not SET
RSV[7:0]
SVN[7:4]
SVN[3:0]
x
Content
Start
Data 1
Data 2
Data 3
Bit 7
0
x
Bit 6
0
x
Bit 5
1
x
SVN[7:4]
Indication is AMIS 49587 is set
Reserved
Software Version Number: major release
Software Version Number: minor release
Not Used
Structure
Bit 4
Bit 3
1
1
x
x
RSV[7:0]
Bit 2
1
x
Bit 1
1
Not SET
Bit 0
1
X
SVN[3:0]
Status Message in SLAVE MODE:
Table 26. STATUS MESSAGE IN SLAVE MODE
Structure
Byte
Content
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
1
Start
0
0
1
1
1
1
1
1
2
Data 1
x
x
x
Not
NEW Not SYNC
Not
Buffer
LOCKED
SET
BUSY
3
Data 2
TS_Nb[2:0]
x
x
x
ALARM
PLL
_EN
_LOCK
4
Data 3
DEP[2:0]
MDC[2:0]
REP[1:0]
Where:
Not LOCKED
NEW
Not SYNC
Not SET
Buffer BUSY
TS_Nb[2:0]
Alarm_EN
PLL_LOCK
DEP[2:0]
MDC[2:0]
REP[1:0]
x
Indication if AMIS 49587 is Unlocked
Indication if AMIS 49587 is New (see definition Section OSI Architecture of AMIS−49587)
Indication of synchronization with mains
Indication if AMIS 49587 is set
Indication if PLC buffer is busy
Time slot counter
Alarm detection status
PLL lock status
Delta Electrical Phase
Minimum Delta Credit Value
Repeater Mode
Not Used
http://onsemi.com