AMIS-49587 Datasheet, PDF (49/59 Pages) ON Semiconductor – Power Line Carrier Modem | |||
|
◁ |
AMISâ49587
WriteConfigNew_Request for Slave Mode
Table 40. DESCRIPTION OF WRITECONFIGNEW_REQUEST IN SLAVE MODE
Field
Length
Value
Description
First Initiator MAC Address (FIMA)
2 bytes
0001 to 0FFF First value for Initiator MAC address
Last Initiator MAC Address (LIMA)
2 bytes
0001 to 0FFF Last value for Initiator MAC address
Local MAC Address
2 bytes
0FFE or
0001 to
(FIMAâ1)
Slave Mode: New
Slave (Registered)
Active Initiator Address
2 bytes
0000
FIMA to LIMA
Slave (unlocked)
Slave (locked on an initiator)
Timeâoutâsynchroâconfirm
Timeâoutâframeânotâok
Timeâoutânotâaddressed
Macâgroupâaddresses
Fs
Fm
R_ZC_ADJUST
NbAlarm
R_ALC_CTRLâValue
Max_Transmistting_GainâValue
R_ALC_CTRLâValue
Max_Transmistting_GainâMode
2 bytes
2 bytes
2 bytes
10 bytes
2 bytes
2 bytes
1 byte
4 bits
(b7 to b4)
3 bits
(b3 to b1)
1 bit (b0)
0000 to FFFF
0000 to FFFF
0000 to FFFF
0000 to 0FFF
0000 to FFFF
0000 to FFFF
00 to FF
XXXX
0000
XXX
In seconds.
In seconds
In minutes (Not used in Master & Monitor mode)
5 MAC group addresses (Not used in Master mode)
Step Register for the Space Frequency Fs
Step Register for the Mark Frequency Fm
Value according to the voltage level of the 50 Hz
information for the input of the PLL.
Number of repetitions of a Phy Alarm
Disable Phy Alarm functionality
Attenuation value in fixed mode
0
Automatic level control
1
Fixed mode
R_CONF_TX_DATA_PRE_SLOT_SEL 1 bit (b7)
0
The output pin is the PRE_SLOT signal or Mode = Master
1
The output pin is the transmitted DATA (for.Radio)
Pad
R_CONFâMODE
R_CONFâBAUDRATE
R_CONFâMAINS_FREQ
1 bit (b6)
3 bits
(b5 to b3)
2 bits
(b2,b1)
1 bit
(b0)
0
This bit is not used (adjust length at 1 byte)
010
Slave mode for server station
00
300 baud @ 50 Hz or 360 baud @ 60 Hz
01
600 baud @ 50 Hz or 720 baud @ 60 Hz
10
1200 baud @ 50 Hz or 1440 baud @ 60 Hz
11
2400 baud @ 50 Hz or 2880 baud @ 60 Hz
0
mains frequency = 50 Hz
1
mains frequency = 60 Hz
Pad
Search method
1 bit (b7)
2 bits
(b6, b5)
0
This bit is not used (adjust length at 1 byte)
0
Method V6
1
Method V3
SINC Filter
SYNCHROâTypeâMode
SYNCHROâBitâValue
SYNCHROâBitâMode
SearchInitiatorGain or
MinâReceivingGain Mode
1 bit (b5)
1 bit (b4)
3 bits
(b3 to b1)
1 bit (b0)
1 bit (b7)
0
1
0
XXX
1
0
Disabled (1111)
Enabled (1331)
Must be set to 0 (Synchronization on subâframe
preamble)
Synchroâbit value (in chip clock) in fixed mode
Must be set to 1 (Fixed synchro bit)
0 Search Initiator Gain selected
1 Min Receiving Gain selected
Search Initiator Gain or
MinâReceiving Gain
MaxâReceivingâGainâValue
3 bits
(b6 to b4)
3 bits
(b3to b1)
XXX
XXX
Value of the gain for Intelligent Synchronisation
or Min Receiving Value
Min Gain of reception = (value * 6 db)
Max Receiving gain value in limited mode
Range of reception = (value * 6 db)
http://onsemi.com
49
|
▷ |