AMISâ49587
Repeater
Description: This request is used to modify the repeater state of the AMISâ49587. The repeater state can be Repeater, No
Repeater, Repeater Isacall or No Repeater Isacall. Only the 2 last bits are used for this command, so the value is in the field
00 to 03.
Request Format :
<STX> Length
41h
0B00h
Repeater State (1 byte)
CHK
Confirm Format:
<STX> Length
42h
0B00h
Repeater State (1 byte)
CHK
Frequency
Description: This request is used to modify the values of the frequencies Fs and Fm used for the PLC communication. See
calculation method Sine Wave Generator on Page 13.
Request Format:
<STX> Length
41h
0C00h
Fs (2 bytes), Fm (2 bytes)
CHK
Confirm Format:
<STX> Length
42h
0C00h
Fs (2 bytes), Fm (2 bytes)
CHK
Data Counters
Description: This request is used to read the value of the data counters in the AMISâ49587. It contains one byte which is used
to know whether the counters must be reset or not (00: no reset, 01: reset)
There are 6 counters coded on 4 bytes each, which indicates:
â Number of CRC OK frames received
â Number of CRC not OK frames received
â Number of repeated frames
â Number of transmitted frames
â Number of corrected frames (with option Pad Correcting)
â Number of frames with bad Frame Indicator received
Request Format :
<STX> Length 41h 0D00h
Request Counters (1 byte) + Pad (0 to 19
bytes)
CHK
Confirm Format :
<STX> Length 42h 0D00h
CRC_OK (4 bytes), CRC_NOK (4 bytes),
Rep_Frames (4 bytes), Tr_Frames (4 bytes),
Corr_Frames (4 bytes), FI_NOK (4 bytes)
CHK
PhyAlarmRequest
Description: This request is used to send a physical alarm pattern. No data is transmitted to indicate the number of repetitions,
the FPMA already knows this number because it is in its config.
Request Format:
<STX> Length 41h
0F00h
Pad (0 to 1 byte)
CHK
Confirm Format:
<STX> Length 42h
0F00h Number of alarm Transmissions (1 byte) CHK
http://onsemi.com