Table 40. DESCRIPTION OF WRITECONFIGNEW_REQUEST IN SLAVE MODE
Field
Length
Value
Description
Max−Receiving−Gain→Mode
1 bit (b0)
0
Non limited Max−Receiving−Gain
1
Limited Max−Receiving−Gain
Time out Inter Character TIC
1 bit (b7)
0
Constant of 10ms
1
5 characters depending on communication speed
Bad CRC transmitting
1 bit (b6)
0
Disables the transmitting of bad CRC frames
1
Enables the transmitting of bad CRC frames
Pad correcting
1 bit (b5)
0
Enables the Pad correcting
1
Disables the Pad correcting
FSK +
1 bit (b4)
0
Disables the improvement of FSK
1
Enables the improvement of FSK
Alarm Filter
1 bit (b3)
0
Enables the alarm filter
1
Disables the alarm filter
Synchro without Gain Min
1 bit (b2)
x
0 disabled
1 enabled
Repeater
2 bits
(b1,b0)
00
Never Repeater or Mode = Master
01
Always Repeater
10
Not Repeater (accept frame ISACall)
11
Repeater (accept frame ISACall)
Time−out−search−initiator
2 bytes
0 to FFFF
In seconds
WriteConfig_Request for Monitor Mode
Table 41. DESCRIPTION OF WRITECONFIGNEW_REQUEST IN MONITOR MODE
Field
Length
Value
Description
First Initiator MAC Address (FIMA)
2 bytes
XXXX
Don’t care
Last Initiator MAC Address (LIMA)
2 bytes
XXXX
Don’t care
Local MAC Address
2 bytes
XXXX
Don’t care
Active Initiator Address
2 bytes
XXXX
Don’t care
Time−out−synchro−confirm
2 bytes
0000 to FFFF In seconds
Time−out−frame−not−ok
2 bytes
0000 to FFFF In seconds
Time−out−not−addressed
2 bytes
XXXX
Don’t care
Mac−group−addresses
10 bytes
0000 to 0FFF 5 MAC group addresses
Fs
2 bytes
0000 to FFFF Step Register for the Space Frequency Fs
Fm
2 bytes
0000 to FFFF Step Register for the Mark Frequency Fm
R_ZC_ADJUST
1 byte
00 to FF
Value according to the voltage level of the 50 Hz informa-
tion for the input of the PLL.
NbAlarm
R_ALC_CTRL→Value
Max_Transmistting_Gain→Value
4 bits
(b7 to b4)
3 bits
(b3 to b1)
XXXX
0000
XXX
Number of repetitions of a Phy Alarm
Disable Phy Alarm functionality
Attenuation value in fixed mode
R_ALC_CTRL→Value
Max_Transmistting_Gain→Mode
1 bit (b0)
0
Automatic level control
1
Fixed mode
R_CONF_TX_DATA_PRE_SLOT_SEL 1 bit (b7)
0
The output pin is the PRE_SLOT signal or Mode = Master
1
The output pin is the transmitted DATA (for.Radio)
Pad
R_CONF→MODE
1 bit (b6)
3 bits
(b5 to b3)
0
This bit is not used (adjust length at 1 byte)
011
Monitor mode to spy and test of the DLC communication
http://onsemi.com