English
Language : 

AMIS-49587 Datasheet, PDF (34/59 Pages) ON Semiconductor – Power Line Carrier Modem
AMIS−49587
TimeoutSynchro
Description: This request is used to modify the value of the timeout synchro confirmation. The Timeout Synchro Confirm is
set in seconds.
Request Format:
<STX> Length
41h
0200h
TO Synchro Confirm (2 bytes)
CHK
Confirm Format:
<STX> Length
42h
0200h
TO Synchro Confirm (2 bytes)
CHK
TimeoutNotOK
Description: This request is used to modify the value of the timeout Frame Not OK. The Timeout Frame Not OK is set in
seconds.
Request Format:
<STX> Length
41h
0300h
TO Frame Not OK (2 bytes)
CHK
Confirm Format:
<STX> Length
42h
0300h
TO Frame Not OK (2 bytes)
CHK
TimeoutNotAddressed
Description: This request is used to modify the value of the timeout Not Addressed. The Timeout Not Addressed is set in
minutes.
Request Format:
<STX> Length
41h
0400h
TO Not Addressed (2 bytes)
CHK
Confirm Format:
<STX> Length
42h
0400h
TO Not Addressed (2 bytes)
CHK
MacGroupAddress
Description: This request is used to modify the values of the 5 Mac Group Addresses. The Mac Group Addresses must be in
the field LIMA(not included) to 0FFB.
If the first address of the 5 MacGroup addresses is set to 0xFFF, every frame with destination MAC address in the field
LIMA(not included) to 0FFB will be transmitted by the FPMA. This makes it possible to manage more than 5 MAC address
of group by the external micro controller.
Request Format:
<STX> Length
41h
0500h Mac Group Addresses (5 *2 bytes)
CHK
Confirm Format:
<STX> Length
42h
0500h Mac Group Addresses (5 *2 bytes)
CHK
Invalid Frame Counter
Description: This request is used to read the Invalid Frame Counter of the AMIS−49587. Once the request sent to the
AMIS−49587, the Invalid Frame counter is automatically set to 0. The AMIS−49587 answers with the value of the Invalid
Frame Counter
Request Format:
<STX> Length
41h
0600h
Pad (0 to 1 byte)
CHK
Confirm Format:
<STX> Length
42h 0600h Invalid Frame Counter (0 to 1 byte)
CHK
http://onsemi.com
34