AMIS-49587 Datasheet, PDF (37/59 Pages) ON Semiconductor – Power Line Carrier Modem | |||
|
◁ |
AMISâ49587
DataStats
Description: This request is used to read the value of the current data statistics in the AMISâ49587. The request contains one
byte which is used to know whether the counters must be reset or not (00: no reset, 01: reset). These statistics are coded this
way:
If the AMISâ49587 is synchronized (30 bytes):
â The value of signal and noise (S0, N0, S1, N1) for the last subframe received (4 * 2 bytes) + the method and gain used
to demodulate this subframe (2 * 1 byte)
â The method, gain and SNR (S0/N0, S1/N1) on the 5 last time slots in reception mode (5 * 4 bytes) + 1 byte to know the
actual position in the table
If the AMISâ49587 is not synchronized (36 bytes):
â The values of the real and imaginary parts of the signal for each frequency (I0, Q0, I1, Q1), for the 4 last calculated
timeâslots (4 * (4 * 2 bytes))
â The current position in the board (1 byte)
â The software reception gain (1 byte)
â The hardware reception gain (1 byte)
â The R_ALC value (1 byte)
Request Format:
<STX> Length 41h
1000h
Reset Counters (1 byte) + Pad (0 to 35
bytes)
CHK
Confirm Format:
If the AMISâ49587 is synchronized:
<STX> Length
42h
1000h
Signal_noise_subframe (10 bytes),
SNRreception (20 bytes)
CHK
If the AMISâ49587 is not synchronized:
<STX> Length 42h 1000h I0,I1,Q1 (32 bytes), Pos (1 byte), GainSoft
(1 byte), GainHard (1 byte), R_ALC (1
byte)
CHK
TimeoutSearchInitiator
Description: This request is used to modify the value of the timeout Search Initiator. The timeout Search Initiator is set in
seconds.
Request Format:
<STX> Length
41h
1100h
TO Search Initiator (2 bytes)
CHK
Confirm Format:
<STX> Length 42h 1100h
TO Search Initiator (2 bytes)
CHK
ReadConfig
Description: This request is used to get an echo of the configuration of the AMISâ49587.
Request Format:
<STX> Length
41h
1200h
Pad (0 to 36 bytes )
CHK
Confirm Format:
<STX> Length
42h
1200h
Pad (0 to 36 bytes )
CHK
http://onsemi.com
37
|
▷ |