APPENDIX D: CODING
PreâDefined Characters
The valid oneâbyte values for the starting characters in the local frame are listed below :
Table 42. PREâDEFINED CHARACTERS
Character
STX
ACK
NAK
?
Definition
Start of text
first char of frame
Acknowledgment
Non Acknowledgment
Start of Status Message
ASCII Code
02h
06h
15h
3Fh
Synchronization State Codes
The valid oneâbyte values for the Synchronization state codes are listed below:
Table 43. SYNCHRONIZATION STATE CODES
New Synchronization State
Primary Code
Secondary Code
Synchronization Found
01
No
Synchronization Confirmed
02
No
Synchronization Lost
04
timeâout not addressed
01
timeâout frame not Ok
02
timeâout synchro confirm
03
Wrong Initiator
04
External Command
05
Search Initiator
06
Error Codes
The valid oneâbyte values for the Error_Code are listed below:
Table 44. ERROR CODES
Error Identifier
ERR_UNAVAILABLE_RESOURCE
ERR_REQUEST_NOT_ALLOWED
ERR_UNAVAILABLE_MODE
ERR_ILLEGAL_DATA_COMMAND
ERR_ILLEGAL_LOCAL_MAC_ADR
ERR_ILLEGAL_INITIATOR_MAC_ADR
ERR_UNAVAILABLE_COMMAND
Request Type
MAC
MAC
LTC/MAC
LTC/DB
LTC/DB
LTC/DB
LTC
Error_Code
11h
12h
21h
22h
23h
24h
25h
Transmission Status
The valid oneâbyte values for the Transmission_Status field are listed below:
Table 45. TRANSMISSION STATUS
Field Name
Value
OK
FFh
LM_TU1
00d
LM_SE
03d
LM_TU2
10d
Description
No error has been found
MA Data Confirm NEG
Resources Temporary Unavailable at the MAC subâlayer
Syntax Error at the MAC subâlayer
Command not authorised or Asic is not synchronised on the mains