English
Language : 

AMIS-49587 Datasheet, PDF (33/59 Pages) ON Semiconductor – Power Line Carrier Modem
AMIS−49587
WriteDB_Confirm (Tag 42h)
Description: The WriteDB_Confirm has to be sent by the FPMA when new data have been correctly recorded. The
DB_Data_Id_Echo contains the identifier of the data and the value read at its memory location. It may have the same structure
as DB_Data_Id or be different (see Section “The Objects Available” for more details on each object).
Syntax:
Initiator
AMIS−49587
Master/Slave
Command (arguments)
WriteDB_Confirm (Data_Config_Echo)
Possible Response
Frame Format:
<STX>
Length
< WriteDB_Confirm >
DB_Data_Id_Echo
CHK
WriteDB_Error (Tag 43h)
Description: The FPMA software checks the MAC addresses, the Synchro−bit and if the modification of that field is allowed.
If it detects an error, it sends back a WriteDB_Error command with the corresponding Error_Code (see Section “The Objects
Available”).
Syntax:
Initiator
AMIS−49587
Master/Slave
Command (arguments)
WriteDB_Error (Error_Code)
Possible Response
Frame Format:
<STX>
Length
< WriteDB_Error >
Error_Code
CHK
THE OBJECTS AVAILABLE
FIMA/LIMA
Description: This request is used to modify the value of the FIMA and LIMA addresses. The values of FIMA and LIMA must
be in the field 0001 to 0FFF, and must be compatible with current value of LocalMacAdd and InitMacAdd.
Request Format:
<STX>
Length
41h
0000h
FIMA (2 bytes),
LIMA (2 bytes)
CHK
Confirm Format:
<STX>
Length
42h
0000h
FIMA (2 bytes),
LIMA (2 bytes)
CHK
LocalMacAdd/InitMacAdd
Description: This request is used to modify the value of the Local Mac Address and the Initiator Mac Address. The values
of LocalMacAdd and InitMacAdd must be in the field 0001 to 0FFF, and must be compatible with current value of FIMA and
LIMA.
Request Format:
<STX>
Length
41h
0100h
LocalMacAdd (2 bytes),
CHK
InitMacAdd (2 bytes)
Confirm Format:
<STX>
Length
42h
0100h
LocalMacAdd (2 bytes),
CHK
InitMacAdd (2 bytes)
http://onsemi.com
33