Display line-scanning
pattern sequence
∼∼∼∼
∼ϒ∼ϒ
ϒϒϒϒ
ϒ∼ϒ∼
∼∼ϒϒ
ϒϒ∼∼
1. to 2.
312
312.5
313
312.5
312
313
2. to 3.
313
312.5
312
312.5
312.5
312.5
3. to 4.
312
312.5
313
312.5
313
312
4. to 5.(1.)
313
312.5
312
312.5
312.5
312.5
Table 74 Display line-scanning pattern sequence
The table below defines the static operation modes for the slave channel. The slave
channel is synchronized to the master channel. Therefore only modes with the same
output line-scanning pattern as the chosen master channel mode are allowed. Several
modes depend on the I²C Bus parameter MEMOP.
STOPMOS
Scan rate conversion algorithm
allowed for
RMODE
000
Median, ABAB
0
001
Frame repetition, ABAB
0
010
Simple 100, AABB
0
011
Field repetition, AAAA I
0
100
Field repetition, AAAA II
0
101
Field repetition, BBBB I
0
110
Field repetition, BBBB II
0
111
not defined
0
000
Median, AB
1
001
Frame repetition, AB
1
010
Line doubling, AB
1
011
Line doubling, AA
1
100
Intra field interpolation A+A*
1
101
Line doubling, BB
1
110
not defined
1
111
Intra field interpolation A+A*, B*+B 1
allowed output
line-scanning
pattern
∼ϒ∼ϒΙ=ϒ∼ϒ∼
∼ϒ∼ϒΙ=ϒ∼ϒ∼
∼∼ϒϒΙ=ϒϒ∼∼
∼ϒ∼ϒΙ=ϒ∼ϒ∼
∼∼∼∼Ι=ϒϒϒϒ
∼ϒ∼ϒΙ=ϒ∼ϒ∼
∼∼∼∼Ι=ϒϒϒϒ
∼Ηϒ
∼Ηϒ
∼Ηϒ
∼Ηϒ
∼Ηϒ
∼Ηϒ
∼Ηϒ
allowed
MEMOP
00 SRC
00 SRC
all
all
all
all
all
00 SRC
00 SRC
all
all
01 SSC
all
01 SSC
Table 75 Static operation modes slave