English
Language : 

LTC3730_15 Datasheet, PDF (4/28 Pages) Linear Technology – 3-Phase, 5-Bit Intel Mobile VID, 600kHz, Synchronous Buck Controller
LTC3730
ELECTRICAL CHARACTERISTICS The ● denotes the specifications which apply over the full operating
temperature range, otherwise specifications are at TA = 25°C. VCC = VRUN/SS = 5V unless otherwise noted.
SYMBOL
PARAMETER
CONDITIONS
MIN TYP MAX UNITS
Operational Amplifier
IB
Input Bias Current
VOS
Input Offset Voltage Magnitude
CM
Common Mode Input Voltage Range
CMRR
Common Mode Rejection Ratio
ICL
Output Source Current
AVOL
Open-Loop DC Gain
GBP
Gain Bandwidth Product
SR
Slew Rate
VO(MAX)
Maximum High Output Voltage
Overtemperature Shutdown
IN+ = IN– = 1.2V, IOUT = 1mA
IOUT = 1mA
IOUT = 1mA
IOUT = 1mA
RL = 2k
IOUT = 1mA
15
200
nA
0.8
5
mV
0
VCC – 1.4
V
46
70
dB
10
35
mA
30
V/µV
2
MHz
5
V/µs
VCC – 1.2 VCC – 0.9
V
TSHDN
Temperature Shutdown
Temperature Rising
130
165
°C
Note 1: Absolute Maximum Ratings are those values beyond which the life
of a device may be impaired. A maximum current of 200µA is allowed to
pull up the RUN/SS pin to prevent overcurrent shutdown.
Note 2: TJ is calculated from the ambient temperature TA and power
dissipation PD according to the following formula:
LTC3730CG: TJ = TA + (PD × 95°C/W)
Note 3: The IC is tested in a feedback loop that includes the operational
amplifier in a unity-gain configuration loaded with 100µA to ground driving
the VID DAC into the error amplifier and servoing the resultant voltage to
the midrange point for the error amplifier (VITH = 1.2V).
Note 4: Dynamic supply current is higher due to the gate charge being
delivered at the switching frequency. See Applications Information.
Note 5: The minimum on-time condition corresponds to an inductor peak-
to-peak ripple current of ≥ 40% of IMAX (see minimum on-time
considerations in the Applications Information Section).
Note 6: The ATTENERR specification is in addition to the output voltage
accuracy specified at VID Code = 11111.
Note 7: This IC includes overtemperature protection that is intended to protect
the device during momentary overload conditions. Junction temperature will
exceed 125°C when overtemperature protection is active. Continuous operation
above the specified maximum operating junction temperature may impair
device reliability.
3730fa
4