English
Language : 

TC1762 Datasheet, PDF (44/114 Pages) Infineon Technologies AG – 32-Bit Single-Chip Microcontroller TriCore
TC1762
Preliminary
Functional Description
MultiCAN Features
• CAN functionality conforms to CAN specification V2.0 B active for each CAN node
(compliant to ISO 11898)
• Two independent CAN nodes
• 64 independent message objects (shared by the CAN nodes)
• Dedicated control registers for each CAN node
• Data transfer rate up to 1Mbit/s, individually programmable for each node
• Flexible and powerful message transfer control and error handling capabilities
• Full-CAN functionality: message objects can be individually
– assigned to one of the two CAN nodes
– configured as transmit or receive object
– configured as message buffer with FIFO algorithm
– configured to handle frames with 11-bit or 29-bit identifiers
– provided with programmable acceptance mask register for filtering
– monitored via a frame counter
– configured for Remote Monitoring Mode
• Automatic Gateway Mode support
• 6 individually programmable interrupt nodes
• CAN analyzer mode for bus monitoring
Data Sheet
40
V1.0, 2008-04