To retain and acquire the absolute position even on
main power failure, iC-PVL monitors VDD and switches
to a battery supply on pin VBAT automatically. The
switching point is just below 3 V. So, if the main supply
voltage on VDD drops below 3 V, the internal circuitry
will be powered by VBAT instead of VDD.
The supply switch features a built-in hysteresis. The
threshold voltages are defined in the Electrical Charac-
teristics: Voff (Item No. 402), the voltage at which the
circuit switches from VDD supply to VBAT supply, and
Von (Item No. 401) for the voltage at which the circuit
switches back to VDD supply.
BAT_MON
Code
0
1*
Note
Addr. 0x03; bit 6
Function
Battery monitoring off
Battery monitoring on
*) Battery monitoring is active during VDD supply.
Table 31: Enable battery monitoring
Depending on the power pack, e.g. a 3.6 V battery
with 1 Ah capacity, the device can operate for several
years. During VDD supply, the iC-PVL monitors the
voltage at pin VBAT to detect a low battery voltage. If
the supply drops below the error threshold Verr voltage
(Item No. 404), an error is generated and signalized at
pin NERR, by the error bit in the SSI communication
protocol, and by the I2C status register. The battery
monitoring function can be enabled/disabled with the
configuration parameter BAT_MON (Table 31).
Additionally, if battery monitoring is enabled by param-
eter BAT_MON, an early battery warning message is
generated. The warning threshold is specified in Vwrn
(Elec. Char. No. 405). If the voltage at pin VBAT
drops below this warning threshold, a warning is gener-
ated and signalized at pin NWRN and optionally by the
warning bit of the SSI data (refer to Table 22).
The thresholds of Verr and Vwrn are defined by Elec.
Char. 404 and Elec. Char. 405. They can be config-
ured with configuration parameter BAT_THR according
to Table 32.
BAT_THR
Code
00*
01
10
11
Notes
Addr. 0x05; bit 3:2
Verr
Vwrn
3.05
3.15
2.95
3.05
2.85
2.95
2.75
2.85
Nominal values. Refer to Elec. Char. 404 and 405
for variation.
*) BAT_THR = 0x00 is recommended.
Table 32: Battery monitor threshold levels