IC-PVL Datasheet, PDF (19/33 Pages) IC-Haus GmbH – LINEAR/OFF-AXIS BATTERY-BUFFERED HALL MULTITURN ENCODER
iC-PVL LINEAR/OFF-AXIS
preliminary
BATTERY-BUFFERED HALL MULTITURN ENCODER
SERIAL INTERFACE MODE (SEL = LOW)
Rev B3, Page 19/33
iC-PVL can be connected to a singleturn sensor or in-
terpolator via its serial interface. To ensure compatibility
with different devices, iC-PVL’s serial interface can op-
erate in two distinct modes: standard SSI or in a chain
mode.
In SSI mode, iC-PVL replies to a multiturn data request
of an SSI protocol master. The master takes care of
data synchronization and calculates a consistent abso-
lute position. Data input DI is not used in this operating
mode. iC-PVL is compatible with all iC-Haus optical
or magnetic singleturn encoders featuring a multiturn
interface (MTI). For details refer to the application ex-
amples of Figure 13 and Figure ?? on Page 28.
In SSI mode, iC-PVL can also be used as stand-alone
magnetic period counter. The position data is output
in an SSI compatible protocol (see Figure 15 on Page
29).
MT_GRAY
Code
0
1
Addr. 0x00; bit 1
Format
Binary code
Gray code
Table 17: Multiturn and PCR output data format via port
DO
Note: The usage of ST_GRAY = 1 in chain mode is
limited. If activated, all data to input DI is converted
to binary code. This conversion may lead to an
unclean ending of the SSI communication. In this
case, instead of a timeout at logic low level, a timeout
at logic high level is received. If this is not appropriate,
the exact singleturn input bit width can be defined by
configuration parameter SYNC_BW which is not used
in chain mode.
In chain mode, a singleturn sensor transmits its single-
turn position to the data input DI of iC-PVL. In this mode,
iC-PVL takes care of synchronization, calculates a con-
sistent absolute position and outputs at data output DO,
comparable to a shift register, with MSB first.
SYNC_BW
Addr. 0x05; bit 1:0
Code
Input bit width
00
all bits (default)
01
14 bit
10
16 bit
11
18 bit
Table 18: Number of expected and converted input
The operating mode is set using parameter INT_MODE.
bits at pin DI with ST_GRAY = 1
INT_MODE
Addr. 0x00; bit 0
Code
Mode
0
Standard SSI read-out mode (SSI mode)
1
Chain mode (chain mode)
Table 15: Serial interface operating mode
The internal multiturn counter is 40 bit wide. In appli-
cations where smaller counter depths are sufficient or
the bit width of the serial interface is limited, the out-
put length of the counter value can be configured with
MT_BW as shown in Table 19.
By default, the iC-PVL expects binary data at input DI,
and also outputs its counted multiturn position (and
PCR) at DO in binary format. In case one data or both
data is required in Gray format, this can be configured
by setting the ST_GRAY bit or the MT_GRAY bit, re-
spectively.
MT_BW
Code
0x00
0x01
...
0x1E
0x1F
Addr. 0x01; bit 4:0
Bit width
9 bit
10 bit
...
39 bit
40 bit
ST_GRAY
Code
0
1
Addr. 0x00; bit 2
Format
Binary code
Gray code
Table 16: Singleturn input data format via port DI (in
chain mode)
Table 19: Bit width of multiturn data and counter
Additionally, iC-PVL can transmit up to 3 synchro-
nization bits, according to configuration parameter
SYNC_BW shown in Table 20.