English
Language : 

IC-PVL Datasheet, PDF (17/33 Pages) IC-Haus GmbH – LINEAR/OFF-AXIS BATTERY-BUFFERED HALL MULTITURN ENCODER
iC-PVL LINEAR/OFF-AXIS
preliminary
BATTERY-BUFFERED HALL MULTITURN ENCODER
Rev B3, Page 17/33
PCR
Code
0x00
0x01
0x02
...
0xFE
0xFF
Addr. 0x02; bit 7:0
Period counts per revolution
1
2
3
Code + 1
255
256
Table 10: Period counts per (mechanical) revolution
By way of example, assume a magnetic code disc with
32 periods. iC-PVL will make a multiturn count every
32 periods. The synchronization bits are distributed
evenly over these 32 periods, i.e. the disc is divided in
eight sectors.Therefore, one sector consists of 8 peri-
ods. While reading the position information, it looks like
the iC-PVL would be placed above a normal diametri-
cally polarized magnet. This scheme is also valid for
non-binary, decimal or odd counts per revolution.
PCR_OUT
Code
0
1
Addr. 0x05; bit 6
Mode
No output of PCR in serial data stream
PCR is transmitted as 8 LSBs of MT data
(Only for PCR > 0x00)
Alternatively, the current magnetic period of the me-
chanical revolution can be transmitted in the serial data
stream with option PCR_OUT = 1. In this mode, the
eight LSBs of the multiturn data are used for PCR out-
put. Unused bits are filled with zeroes. As a conse-
quence, the multiturn counter is limited to 32 bits in this
mode. The multiturn, PCR and synchronization infor-
mation give the exact position of the code disc down to
one eighth of a magnetic period.
Even as iC-PVL is particularly designed for off-axis
scanning of magnetic pole wheels, it can also be used
for on-axis scanning of a diametric cylindrical magnet.
The on-axis scanning mode is activated with the con-
figuration bit ONAX = 1. The sensor circle diameter
is specified in Elec. Char. 106. In this mode, setting
POLEWID to 0x01 is mandatory for differential scan-
ning.
ONAX
Code
0
1
Addr. 0x04; bit 2
Magnetic scanning mode
Off-axis (default)
On-axis, differential (POLEWID = 0x01 required)
Table 12: Use off- or on-axis magnetic scanning
Table 11: Period count per revolution output mode