English
Language : 

IC-PVL Datasheet, PDF (15/33 Pages) IC-Haus GmbH – LINEAR/OFF-AXIS BATTERY-BUFFERED HALL MULTITURN ENCODER
iC-PVL LINEAR/OFF-AXIS
preliminary
BATTERY-BUFFERED HALL MULTITURN ENCODER
The I2C multimaster tries to read the configuration data
from an EEPROM connected to SCL and SDA. When
the data is read without errors, the iC-PVL operates in
SSI Mode or Chain Mode according to the configuration
bit INT_MODE and stays in this operating mode as long
as the battery supply is above Voff . After a third faulty
attempt, EEPROM read-out is stopped and an error is
indicated at pin NERR. Both serial interface modes are
further explained on Page 19. I2C communication is
possible in this operating mode, but position read-out
via SSI or I2C is exclusive (refer to I2C SLAVE MODE
on Page 23).
If SEL is shorted to input PRE, the device directly boots
into I2C slave mode without any activity on the I2C lines.
iC-PVL now responds to the I2C ID = 0b1100 001.
Rev B3, Page 15/33
Note: After installation of the battery, it is important
to put iC-PVL into a valid operating state to prevent
the battery from an excessive current drain. To do
so, a suitable magnetic target needs to be installed,
the main supply VDD powered, and a preset pulse
applied to input PRE.
Note: A magnetic field according to the specifications
should be provided any time (see Elec. Char. No.
102). If a suitable magnetic target can not be provided
during shipment or storage, use the sleep command
(refer to Table 30) or disconnect the battery.