English
Language : 

SAP5SD-A-G1-T Datasheet, PDF (50/63 Pages) List of Unclassifed Manufacturers – Universal Actuator-Sensor Interface IC
SAP5S / SAP51
Universal Actuator-Sensor Interface IC
D0/D2 high level
VUOUT
VIH Min (3.5V)
D0/D2 low level
Offset
VOFH = VIL2 Max (2.5V)
VOFH = VIL2 Min (1.6V)
VOFL Max (1.0V)
VOFL Min (0.0V)
Figure 12: Data Input Voltage Constraints in Safety Mode
As soon as the F-D0* input pad detects an offset level less than VOFL(Max) the SAP5 resets the data input for
D1 (F-D1*), signalling an OPEN state at the safety switch connected to D0*. The input data for D3 (F-D3*) will
be reset if the F-D2* detects an offset level less than VOFL(Max), respectively.
Provided that the offset levels are not missing, the E2PROM bits D1* and D3* are transmitted as data bits D1
and D3 if swap_flag = ‘0’, otherwise they are swapped.
In order to avoid desynchronization with the safety monitor in case the AS-i master repeats a DEXG call, the
SAP5 will not update the data code word for 224s (+16s) after a DEXG call had been processed.
Data Sheet
July 17, 2012
© 2012 Zentrum Mikroelektronik Dresden AG — Rev. 3.1
All rights reserved. The material contained herein may not be reproduced, adapted, merged, translated, stored, or used without
the prior written consent of the copyright owner. The information furnished in this publication is PRELIMINARY and subject to
changes without notice.
50 of 62