English
Language : 

SAP5SD-A-G1-T Datasheet, PDF (19/63 Pages) List of Unclassifed Manufacturers – Universal Actuator-Sensor Interface IC
SAP5S / SAP51
Universal Actuator-Sensor Interface IC
2.3.12. Summary of Master Calls
In and Table 7 on the following pages show the complete set of master calls that are decoded by the SAP5 in
Slave Mode. The master calls in Table 7 are intended for programming of the IC by the slave manufacturer
only. They become deactivated as soon as the Lock_EE_PRG and Safety_Program_Mode_Disable flag are
set in the Firmware Area of the E²PROM.
AS-i Complete Specification compliance note:
In order to achieve full compliance to the AS-i Complete Specification, the Program_Mode_Disable flag must
be set by the manufacturer of AS-i slave modules during the final manufacturing and configuration process
and before an AS-i slave device is delivered to field application users.
Data Sheet
July 17, 2012
© 2012 Zentrum Mikroelektronik Dresden AG — Rev. 3.1
All rights reserved. The material contained herein may not be reproduced, adapted, merged, translated, stored, or used without
the prior written consent of the copyright owner. The information furnished in this publication is PRELIMINARY and subject to
changes without notice.
19 of 62