English
Language : 

SAM9260_14 Datasheet, PDF (674/784 Pages) ATMEL Corporation – AT91SAM ARM-based Embbedded MPU
38.5.3 ISI Status Register
Register Name: ISI_SR
Access Type: Read
Reset Value: 0x0
31
30
29
28
27
26
25
24
–
–
–
–
–
–
–
–
23
22
21
20
19
18
17
16
–
–
–
–
–
–
–
–
15
14
13
12
11
10
9
8
–
–
–
–
–
–
FR_OVR
FO_C_EMP
7
6
5
4
3
2
1
FO_P_EMP FO_P_OVF FO_C_OVF CRC_ERR
CDC_PND
SOFTRST
DIS
0
SOF
• SOF: Start of frame
0: No start of frame has been detected.
1: A start of frame has been detected.
• DIS: Image Sensor Interface disable
0: The image sensor interface is enabled.
1: The image sensor interface is disabled and stops capturing data. The DMA controller and the core can still read the
FIFOs.
• SOFTRST: Software reset
0: Software reset not asserted or not completed.
1: Software reset has completed successfully.
• CDC_PND: Codec request pending
0: No request asserted.
1: A codec request is pending. If a codec request is asserted during a frame, the CDC_PND bit rises until the start of a new
frame. The capture is completed when the flag FO_C_EMP = 1.
• CRC_ERR: CRC synchronization error
0: No CRC error in the embedded synchronization frame (SAV/EAV)
1: The CRC_SYNC is enabled in the control register and an error has been detected and not corrected. The frame is dis-
carded and the ISI waits for a new one.
• FO_C_OVF: FIFO codec overflow
0: No overflow
1: An overrun condition has occurred in input FIFO on the codec path. The overrun happens when the FIFO is full and an
attempt is made to write a new sample to the FIFO.
• FO_P_OVF: FIFO preview overflow
SAM9260 [DATASHEET]
6221K–ATARM–15-Oct-12
674