ABSOLUTE MAXIMUM RATINGS
Parameter
Symbol
Min
Max
DC Supply(TV+1,TV+2,RV+1,RV+2,AV+,DV+)(Note 1)
-
6.0
Input Voltage
Any Pin
Vin
RGND-0.3 (RV+)+0.3
Input Current
Any Pin
(Note 2)
Iin
-10
10
Ambient Operating Temperature
TA
-40
85
Storage Temperature
Tstg
-65
150
WARNING:Operations at or beyond these limits may result in permanent damage to the device.
Normal operation is not guaranteed at these extremes.
Notes: 1. Referenced to RGND1,RGND2,TGND1,TGND2,AGND,DGND at 0V.
2. Transient currents of up to 100 mA will not cause SCR latch-up.
Units
V
V
mA
oC
oC
RECOMMENDED OPERATING CONDITIONS
Parameter
Symbol Min
Typ
Max Units
DC Supply(TV+1,TV+2,RV+1,RV+2,AV+,DV+)
Ambient Operating Temperature
(Note 3)
3.135
3.3
3.465
V
TA
-40
25
85
oC
Power Consumption T1
(Notes 4 and 5) PC
-
292
380 MW
(Each Channel)
T1
(Notes 4 and 6)
-
167
220 MW
E1,75ohm (Notes 4 and 5)
-
180
210 MW
E1,120ohm (Notes 4 and 5)
-
170
200 MW
REFCLK Frequency
T1
1XCLK=1
1.544- 1.544 1.544+ MHz
100ppm
100ppm
T1
1XCLK=0
12.352- 12.352 12.352+ MHz
100ppm
100ppm
E1
1XCLK=1
2.048- 2.048 2.048+ MHz
100ppm
100ppm
E1
1XCLK=0
16.384- 16.384 16.384+ MHz
100ppm
100ppm
Notes: 3. TV+1,TV+2,AV+,DV+,RV+1,RV+2 should be connected together.TGND1,TGND2,RGND1,
RGND2,DGND1,DGND2,DGND3 should be connected together.
4. Power consumption while driving line load over operating temperature range. lncludes IC and load.
Digital input levels are within 10% of the supply rails and digital outputs are driving a 50 pF
capacitive load.
5. Assumes 100% ones density and maximum line length at 3.465V.
6. Assumes 50% ones density and 300ft. line length at 3.3V.